Cannon QL Pre-SetAperture and Checking of Depth-of-Field, Relation Between the Pellicle Mirror, CdS, Diaphragm and Shutter, Lens with A-MRing

Page 8

è

 The aperture ring can also be set to intermediate values.

 

è

 Depending on the lens, there are instances where there is no relation to the lightness being halved between the maximum diameter of 

the aperture and the next aperture reading.

 

è

 The ratio between aperture and the amount of exposure, using F 2 as the basis, is as follows:

 

Lens Aperture

1.2 1.4 1.8 2 2.8 3.5 4 5.6 8 11 16 22 

Exposure Ratio 

3 2 1.25 1 1/2 1/3 1/4 1/8 1/16 1/32 1/64 1/128 

Pre-Set Aperture and Checking of Depth-of-Field

 

Lens with A-M Ring

 

1.    Pre-Setting of Aperture: Set the A-M ring at "A". Then set the desired F stop on the pre-set aperture ring to the index. The 

diaphragm will close down to the pre-set F stop only for the instant that the shutter is released. Except for the instant that the shutter is 

released, the diaphragm will remain fully open.

 

2.    Manually Operated Aperture: When the ~ A-M ring is set at "M" the diaphragm closes down to the pre-set F stop. In this way the 

depth-of-field at the time of shutter release can be checked. When the A-M ring is reset at "A" the diaphragm again returns to maximum 

opening. 

Lens with Manual Aperture Ring

 

1.    Pre-setting of aperture: Set the desired F stop on the pre-set aperture ring to the index. Then set the index of the manual aperture 

ring to this pre-set F stop. The diaphragm will close down to the pre-set F stop only for the instant that the shutter is released.

 

2.    Manually Operated Aperture: When the ~ manual aperture ring is turned in the direction of closing down the diaphragm, after 

setting the desired F stop on the preset aperture ring to the index, the diaphragm will close down to the pre-set F stop and the depth-of-

field can be checked. The manual aperture ring cannot be turned when set at maximum aperture opening. 

è

 Refer to pages 34-35 concerning depth-of-field.

www.4.butkus.org

 

Relation Between the Pellicle Mirror, CdS, Diaphragm and Shutter 

Image 8
Contents Before Using Canon PellixCamera Manual To main Chinon/Ricoh manual siteTable of contents Technical Data Technical Data — page 4 Battery Check Mercury Battery Loading :Safety Device for Shutter Film CounterAttaching the Cable Release Film Winding :Lens Aperture Shutter and Aperture Adjustment :Shutter Speed Dial Pre-Set Aperture and Checking of Depth-of-Field Relation Between the Pellicle Mirror, CdS, Diaphragm and ShutterLens with A-M Ring Lens with Manual Aperture RingHow to Use Built-in Exposure Meter : Film Speed SettingCdS Actuating Lever Exposure Setting 1--Shutter Speed Priority Method :How to Measure the Average Brightness Exposure Setting 2--F Stop Priority Method : Focusing : Holding the Camera : Composition and ViewfinderHolding the Camera : — page 14 Film Loading : Film Rewinding : Setting the Film SpeedChecking Correct Film Loading Flash Synchronization : Photography Using Self-timer and Eyepiece Shutter :Eyepiece Shutter Uses of Lenses : Changing LensesDistance Scale Infrared Index " R "Film Plane Mark Depth of field ScaleLens Mount (FL and R Series Lenses) Filters : Double Exposure :Cleaning of the Camera Cleaning the LensProper Care of the Canon PELLIX QL : Storage of CameraInterchangeable Lenses and Accessories : Canon Interchangeable LensesCanon Zoom Lenses New "Compact Series" LensesCanon Booster AccessoriesTechnical Data Technical Data — page 24