Cannon QL Mercury Battery Loading, Battery Check, Check

Page 5

Mercury Battery Loading 

Load the mercury battery into the battery compartment. The mercury battery powers the built in CdS exposure meter, and the meter will 

not function unless the battery is in position.

 

1.    Press the finger against the battery cover and turn to the left to remove.

 

2.    Face the central contact of the mercury 2 battery inwards and insert, then screw the cover back in. 

è 

Before insertion, clean mercury battery thoroughly with a dry cloth. Perspiration or finger marks may cause corrosion and may 

prove particularly harmful to center of contact. Un. clean battery may also damage the contact point of the camera.

è 

For mercury battery, National M-ID or Toshiba TM-MC is used -equivalent to Mallory RM-625R, Eveready E625N, GE #625. 

Life of the battery in continuous use is approximately one year. 

è

 When inserting, do not confuse the (+) ( - ) Not only will the meter fail to function in case of reverse insertion, but the cover cannot 

be screwed in properly. 

è

 When not in use for a long period, remove the battery and keep in a dry place. 

Battery Check 

Check the mercury battery after loading it. Especially when loading a new battery, be sure to check the voltage.

 

1.    Set the film speed graduation of the shutter dial at ASA 100 and set "X" et the index mark. Lift up the outer sensitivity ring of the 

shutter dial and turn. See page 16.

 

è

 An accurate check cannot be made if settings other than those mentioned above are used.

 

2.    Turn the check ring on the outer side of the film rewind knob and set " C" at the index mark.

 

3.    If the meter needle inside the viewfinder swings up to or over the c index, it means there is sufficient voltage. If the needle stays 

below the edge of the 0 index, voltage is insufficient and the battery must be replaced.

 

è

 In the Canon PELLIX QL, the electric current flows only when the CdS actuating lever is pressed. 

www.butkus.org/chinon

Image 5
Contents Canon Pellix Before UsingCamera Manual To main Chinon/Ricoh manual siteTable of contents Technical Data Technical Data — page 4 Mercury Battery Loading : Battery CheckFilm Counter Safety Device for ShutterAttaching the Cable Release Film Winding :Lens Aperture Shutter and Aperture Adjustment :Shutter Speed Dial Relation Between the Pellicle Mirror, CdS, Diaphragm and Shutter Pre-Set Aperture and Checking of Depth-of-FieldLens with A-M Ring Lens with Manual Aperture RingFilm Speed Setting How to Use Built-in Exposure Meter :CdS Actuating Lever Exposure Setting 1--Shutter Speed Priority Method :How to Measure the Average Brightness Exposure Setting 2--F Stop Priority Method : Focusing : Composition and Viewfinder Holding the Camera :Holding the Camera : — page 14 Film Loading : Film Rewinding : Setting the Film SpeedChecking Correct Film Loading Flash Synchronization : Photography Using Self-timer and Eyepiece Shutter :Eyepiece Shutter Changing Lenses Uses of Lenses :Distance Scale Infrared Index " R "Film Plane Mark Depth of field ScaleLens Mount (FL and R Series Lenses) Double Exposure : Filters :Cleaning the Lens Cleaning of the CameraProper Care of the Canon PELLIX QL : Storage of CameraCanon Interchangeable Lenses Interchangeable Lenses and Accessories :Canon Zoom Lenses New "Compact Series" LensesCanon Booster AccessoriesTechnical Data Technical Data — page 24