Cannon QL Exposure Setting 2 --F Stop Priority Method

Page 11

è

  Canon's TTLM system has been adopted in the PELLIX QL which provides the most accurate photometry. Under this system, the 

CdS photocell of the built-in meter is placed in the closest position to the film on the back side of the panicle mirror.

 

è

  The rectangular frame on the outside of the prism screen within the viewfinder is the same size as the light receiving area of the CdS 

photocell. Place the center of the photographic subject within this frame and measure the intensity of light. In this way the photographer 

can decide the best exposure for his photographic needs. The TTLM system makes possible the measuring of exposures in counter-light 

conditions.

 

è

  Measurement at "B" and "X" indexes of the shutter dial is not possible with the exposure meter because " B " is used for long 

exposures over one second and " X " is used for speedlight. 

Exposure Setting 2 -- F Stop Priority Method 

1.  Set the lens aperture at the desired F stop.

 

2.  Face the camera towards the photographic subject, look into the viewfinder, and press the CdS actuating lever.

 

3.  While pressing or locking the CdS actuating lever, turn the shutter dial.

 

4.  Set the meter needle at the o index within the viewfinder for correct exposure. 

è

  Intermediate positions on the shutter speed dial scale cannot be used, but since any aperture may be utilized, the shutter speed 

should first be determined when strictly considering the exposure. It is most practical to adjust the aperture according to this.

 

è

  During the use of the meter, there are instances of the movement of the needle becoming slack, owing to changes in the degree of 

light, but this is due to the characteristics of the CdS.

 

è

  When taking pictures against light, always use a lens hood.

 

è

  When the subject is too bright or too dark and is outside the coupling range of the built-in exposure meter, the meter needle will 

point to the top of the viewfinder and will indicate that proper exposure cannot be obtained. Refer to " Coupling Range of Built-in 

Exposure Meter " on the following page. 

www.butkus.org/chinon

Image 11
Contents To main Chinon/Ricoh manual site Before UsingCanon Pellix Camera ManualTable of contents Technical Data Technical Data — page 4 Mercury Battery Loading : Battery CheckFilm Winding : Safety Device for ShutterFilm Counter Attaching the Cable ReleaseLens Aperture Shutter and Aperture Adjustment :Shutter Speed Dial Lens with Manual Aperture Ring Pre-Set Aperture and Checking of Depth-of-FieldRelation Between the Pellicle Mirror, CdS, Diaphragm and Shutter Lens with A-M RingFilm Speed Setting How to Use Built-in Exposure Meter :CdS Actuating Lever Exposure Setting 1--Shutter Speed Priority Method :How to Measure the Average Brightness Exposure Setting 2--F Stop Priority Method : Focusing : Composition and Viewfinder Holding the Camera :Holding the Camera : — page 14 Film Loading : Film Rewinding : Setting the Film SpeedChecking Correct Film Loading Flash Synchronization : Photography Using Self-timer and Eyepiece Shutter :Eyepiece Shutter Infrared Index " R " Uses of Lenses :Changing Lenses Distance ScaleFilm Plane Mark Depth of field ScaleLens Mount (FL and R Series Lenses) Double Exposure : Filters :Storage of Camera Cleaning of the CameraCleaning the Lens Proper Care of the Canon PELLIX QL :New "Compact Series" Lenses Interchangeable Lenses and Accessories :Canon Interchangeable Lenses Canon Zoom LensesCanon Booster AccessoriesTechnical Data Technical Data — page 24