⬛ Alarm Output Terminal
Connect this terminal to alarm devices such as an annunciator, indicator, lamp or buzzer.
(Alarm Output Equivalent Circuit)
|
| Alarm Device | |
|
| Connection | |
|
| Example | |
OUT |
| DC 12 V | |
IN | R | ||
Terminal | |||
Grounding |
| ||
Terminal |
|
| |
| GND |
|
Output Requirements
•Equivalent to NPN open collector output (Set output logic using the controller)
•Allowed applied voltage: DC12V and below
•Allowed input current: 50 mA
•Momentary output: 1 to 5000ms (Set duration using the controller)
Caution
Connect the grounding terminal of
3. Connection of LAN Cables
Use the LAN cable to connect this camera to a hub or PC
When connecting to a hub make use of a straight cable. When connecting to a PC make use of a cross cable.
Caution
The use of a cross cable may not be supported by certain LAN boards on some rare occasions. As such, please check your LAN board specifications before connection.