Operations (Step 3 Setting Using the V.Networks Controller)

3-5 Image Quality Setting (Continued)

Lens

 

Item

 

Function/Set Value

Initial Value

 

 

 

 

Iris

 

Set the method for adjusting the lens iris.

Auto

 

 

Auto

: Adjusts iris automatically to the default state.

 

 

 

Auto+

: Adjusts iris automatically to a level brighter than

 

 

 

 

the default state.

 

 

 

Auto-

: Adjusts iris automatically to a level darker than the

 

 

 

 

default state.

 

 

 

Manual

: Use this setting to adjust the iris manually.

 

Focus

 

Adjusts the focus.

Easy AF

 

 

Easy AF

: Adjusts the focus automatically during the Pan/Tilt

 

 

 

 

or Zoom operation of the camera.

 

 

 

Manual

: Adjusts the focus manually. Move the slider to the

 

 

 

 

left to adjust focus on a distant object, and move

 

 

 

 

to the right to focus on a near object.

 

Zoom

 

For performing Zoom operation.

 

 

Object enlarges in size towards the Tele-end and reduces to-

 

 

 

wards the Wide-end.

 

66

Image 66
Contents VN-C625 Safety Precautions Important Safeguards Contents Introduction Preparation SettingsOperating Using a Web Browser Setting Using the V.Networks ControllerOperating Using the V.Networks Controller OperationCharacteristics Operating Precautions Consumable Parts  Zooming operationOperating Precautions Items Included Latest UpdatesPC Specifications Operating EnvironmentName and Function of Parts Clamping Holes x Fastening Hook for Safety WireCeiling Mount Camera Terminal Side # Camera Clamping BracketNetwork Connection Connection ExamplesLAN Connection Peer-to-Peer ConnectionPreparation Procedure Set the camera in the following procedureConnecting Cables Make a hole in the ceilingRemove the cover Lead the cable through the cover Connect the cable to this cameraAttach the cover Connecting Cables Cable Specifications Alarm Input Terminal Output Requirements Connecting a 5C-2V or 3C-2V coaxial cable Connection of Coaxial CablesDisconnect the connector from the sup- plied Converter Unit Connecting multiple VN-C625 CamerasAttach safety wire to prevent camera from falling down Attachment of Ceiling MountFront Inserting the CF card Attach the CF cover dismantled in StepList of Tested CF Cards Installing the Camera Installing the Camera Turn the cameraFasten the locking screw Installing the Software Installing the V.Networks ControllerInstalling the VN-C625U Setup Tool Setting PCs IP Address Windows XP ClickSelect Internet Protocol TCP/IP and click Properties Click on the Local Area Connection Properties screenSetting PCs IP Address Windows Click Settings Network Settings Check settings Start up the V.Networks Controller.Other Settings Using the VN-C625U Setup Tool Authorization Level Allowed Access Following confirmation screen will be displayedOther Settings Using the VN-C625U Setup Tool 2. Multicast MulticastMulticast Address Search screen is displayed Start up the VN-C625U Setup ToolV.Networks Search screen is displayed Search result is displayedAlarm Input Operation when an alarm input is activatedStart up the VN-C625U Setup Tool and select Alarm Page Alarm Output Alarm 1/AlarmDetect Mode Go to a presetRelay Alarm Alarm 1/Alarm Message PacketAlarm FTP Available Other Triggers Preset PositionPosition Return Mode List Alarm Output Setting the Trigger Recording screen Setting the Frame Rate screenExample Setting the Advance screen Recording timeRecording files Start up the VN-C625U Setup Tool and select Private Mask When all the settings have been completed, click to endWhen setting is complete, click Fixed area Free areaPerform area setting Other Settings Using the VN-C625U Setup Tool 8. Web Displaying still images uploaded to the /user folderOther Settings Using the VN-C625U Setup Tool 9. FTP Server Start up the VN-C625U Setup Tool and select FTP ServerContinuous FTP Trigger FTPRec File Transfer error PasswordError recovery Connection error Alarm FTP Upload SettingMode Black and White TimeOne Push AF Auto LevelLight Start up the VN-C625U Setup Tool and select Time When NTP is usedStart up the VN-C625U Setup Tool and select Memory Info Start up the VN-C625U Setup Tool and select Auto ReturnNormal High SpeedConnect to VN-C625 Settings Setting Using the V.Networks Controller Starting Up V.Networks ControllerFeatures that Allow Setting Using the V.Networks Controller Features that Allow Setting Using the V.Networks Controller 4Setting Quality5Help About Motion Detection Standby Select File and Motion Detection Standby Select a cameraSelect View Specify Image Size and Upside Down settings Image Size and InversionImage Quality Setting Image Quality Setting  Image Quality Setting Set value Average PeakLarge Peak value ShutterImage Quality Setting  Lens Select Setting and Frame rate Set the Frame Rate Frame RatePreset Position Setting Select Setting and Position MemoryAlarm Setting Alarm Setting Variable Pan/Tilt SettingPan/Tilt Speed Speed 1 to SpeedAuto Pan Setting Select Setting and Auto Pan SettingPerform setting Close the windowAuto Patrol Setting Select Setting and Auto Patrol SettingAuto Patrol No Auto Trace Setting Select Setting and Auto Trace SettingStart to memorize operation Close the window Select Setting and Time Stamp Perform setting Time StampSelect Setting and Property Perform setting When alteration is complete, clickChanging Registered Information Buttons for position moving Snap ShotZoom button and Zoom bar # Pan/Tilt/Zoom Position IndicatorPan/Tilt button Angle StepClick the Stop button Record/StopClick the REC button Motion Image WindowPlayback Playback Click Playback screen is displayed Record/Playback Time Image Size Data Size Per Image Approximate Recording TimeSnap screen will be displayed SnapshotClick the Snap Shot button Save As screen is displayedLAN Environment Web Page ImagesAccess Authorization Level Authentication of Access AuthorizationStarting Up the Web Browser Start up the web browserTop page will be displayed Setting Using the Web Browser Display the TopTop Settings page will be displayed Setting Using the Web Browser 1. Other Settings Other settingsSetting Using the Web Browser 1. Other Settings Http port number, check using the setup tool supplied # NTP SettingsSetting Using the Web Browser 2. Control Setting Using the Web Browser 3.Image Setting Manual Focus Level Iris ModeAGC AveragePeakSetting Using the Web Browser 4. PAN/TILT Setting 1Low, 2 to 7, 8FastAccording to ZOOM, speed of operation is made variable Setting Using the Web Browser 5. Position Memory Setting Image Settings ScreenSetting Using the Web Browser 6. View Setting Resolution100 Setting Using the Web Browser 7. Alarm Setting 101 Alarm Out Setting Using the Web Browser 8. FTP Setting 103Setting Using the Web Browser 8. FTP Setting Setting Using the Web Browser 9. Auto Pan Setting Duration Setting Using the Web Browser 10. Auto Patrol SettingPosition Number 106For setting image quality Setting Using the Web Browser 11. Auto Trace SettingRecord Start Confirmation Screen Image Settings Screen 107Setting Using the Web Browser 12. Black & White Setting Setting Using the Web Browser 13. Schedule Setting108 Setting Using the Web Browser 14. Private Mask Setting Mask Position and Size Controller 109Right Side Left Side Setting Using the Web Browser 15. Limit SettingFunction Tilt LimitSetting Using the Web Browser 16. Auto Return Setting Return Action111 Viewing Still Images 112Viewing Live Images 113Image Link Displaying a still image114 Troubleshooting Symptom Causes/Remedial Actions115 Troubleshooting 116Lens SpecificationsCamera Rotating Table Pan/Tilt Mechanism General Ceiling Mount Hole Unit mm VN-C625 Dome Type Network Camera