6. SETTING ON THE MENU SCREEN (Cont’d)
PROCESS SCREEN (Cont’d)
| Item |
| Functions and operation | Variable values |
|
|
|
| |
GAMMA | It sets the compensation of the GAMMA curve which decides the reappearance of | ON | ||
|
| black. | OFF | |
|
| ON | : The compensation of the GAMMA curve is carried out. (Normal monitor is used.) |
|
|
| OFF : The compensation of the GAMMA curve is not carried out. |
| |
|
|
|
| |
FLARE<R> | When flare occurs, a phenomenon in which the whole screen becomes | +127 | ||
|
| because of irregular light reflection in a lens, the, R ch. of the black level can be | to | |
|
| compensated. Carry this out together with the adjustment of the FLARE <B>. | NORMAL | |
|
| To increase red : Increase the numbers. | to | |
|
| To decrease red : Decrease the numbers. | ||
|
|
|
| |
FLARE<B> | It compensates the B ch. of the black level for the flare occurrence. | +127 | ||
|
| To increase blue : Increase the numbers. | to | |
|
| To decrease blue : Decrease the numbers. | NORMAL | |
|
|
|
| to |
|
|
|
| |
|
|
|
| |
ABL | It sets the black level auto adjustment of video signal during recording.Adjust this | OFF | ||
|
| when the black level varies when shooting images. | ADJUST | |
|
| OFF | : ABL adjustment cannot be carried out. |
|
|
| ADJUST : ABL adjustment can be carried out. |
| |
|
|
|
| |
| ABL | This sets the ABL adjustment level. | +127 | |
| LEVEL | (It is available only when the ABL is set to the ADJUST.) | to | |
|
| To increase black level : Increase the numbers. | NORMAL | |
|
| To decrease black level : Decrease the numbers. | to | |
|
|
|
| |
|
|
|
|
|
24