Panasonic AW-HE870N operating instructions Depth 3/8˝ 10 mm

Page 20

Mounting

The connection and installation should be done by qualified service personnel or system installers. Refer any servicing to qualified service personnel.

Mounting the camera onto a pan-tilt head, tripod, camera mounting bracket, or other part

1.Use the camera mounting screw holes to mount onto a pan-tilt head, tripod, camera mounting bracket, or other part.

2.Fit the supplied mounting spacer into the camera mounting screw holes on the camera’s top surface when mounting the camera with its bottom surface, or on the camera’s bottom surface when mounting the camera with its top surface, and attach the drop-prevention wire using the mounting screw (M4).

When the unit is to be mounted onto a Panasonic pan-tilt head, use the mounting screws and drop-prevention wire that are supplied with the pan-tilt head.

When the unit is to be mounted onto a tripod, camera mounting bracket, or other part, refer to page 14, and provide your own drop-prevention wire, mounting screws, and washers.

Camera mounting screw holes

(Inch screws: 1/4-20UNC),

Depth: 3/8˝ (10 mm)

Camera mounting adapter

- 20 -

Image 20
Contents Installation instructions provided Operating InstructionsFCC Note Risk of Electric Shock Do not OpenPage Important Safety Instructions Contents Changing the settings Menu item setting/changingMenu item setting/changing User Mode Standard accessories PrefaceOperating Instructions DC cable 9.84 ft m Mounting spacerFeatures  Down converter a standard featureSpecial notes on operation Precautions for use DON’TSDOS Concerning electromagnetic interference Precautions for installationConcerning the installation location of the camera Concerning the mounting screws and drop-prevention wire Tightening the mounting screws and mounting spacer Drop-prevention wire Parts to be provided by the customer for installation Mounting screws M4 For attaching the drop-prevention wire Major operating controls and their functions Front view / Top view / Rear view / Bottom viewFront view Top view Rear view Bottom view  Menu switch Menu  ENTER/AWB switch ENTER/AWB Lens mount  Lens fixing ring knob UP/ABB switch UP/ABB  Video output connector Video OUT Iris connector Iris  DOWN/BAR switch DOWN/BAR DC 12 V input connector 12 V  G/L input connector G/L Cable clamp  Optional card slot Option CardLens mounting When the pan-tilt head has been usedMounting Depth 3/8˝ 10 mm Wall  Example where the camera is mounted on a ceiling or wallCeiling  Example of mounting on a surface above Camera Camera mounting bracket Mounting spacer suppliedIndoor Pan/tilt Head AW-PH400 System configuration Connections Video OUTWhen an SDI card AW-HHD870 has been installed Connection of a remote operation panelInput Output Connection of the Indoor Pan-tilt Head AW-PH360  AW-IF400 Switch settings when the AW-RP400 is used HD/SD-SDI Connection of the Indoor Pan-tilt Head AW-PH400 SW1 SW2 SET UP 10BASE-T Connection of the Indoor Pan-tilt Head AW-PH405  AW-IF400 Switch settings when the AW-RP400 is used HD/SD HD/SD-SDI Connection of the Outdoor Pan-tilt Head AW-PH650  AW-IF400 Switch settings when the AW-RP400 is used HD/SD How to operate the system Control exercised from the Remote Operation Panel AW-CB400How to operate the system Procedure for camera menu operation AW-CB400 Jog dial main How to operate the system Procedure for camera menu operation AW-RP655 How to operate the system Mode How to operate the system Procedure for camera menu operation AW-RP555 Use mode setting Use Mode SettingSelecting Take the shots Operating procedureAdjust the black balance Adjustment Flange back adjustment For zoom lensAutomatic iris power zoom lens Iris gain control in a lensWhite balance adjustment  Automatic white balance control AWB AWB A/AWB B Preset of 3200K or 5600K white balance  Automatic tracking white balance setting ATW Manual white balance setting Black balance adjustment Total pedestal level adjustment When adjusting the phase of HD signals Genlock adjustment Horizontal phase control When adjusting the phase of SD signals Adjustment by camera menu Color phase adjustment  Setting when using the camera by itself Menu item setting/changingMenu item setting  Main menu screen Main menu of Halogen, Fluorescent, Outdoor ModeMain menu of User Mode Sub menu Halogen, Fluorescent, Outdoor Mode Description of the setting screen  Detecting ratio adjustment Light PEAK/AVG P50 to A50 Gain setting Gain Auto, -6 dB to 18 dB  AGC maximum gain setting AGC Max Gain 6 dB, 12 dB, 18 dB Black level setting Pedestal -150 to +150 DB to -1 dB Color Set  Chroma level adjustment Chroma Level -3 to +3  Skin color adjustment Flesh Tone -3 to +3 Clean DNR setting Clean DNR Off, Low, High  Detail level setting Level Off, Low, High Subcarrier phase fine adjustment SC Fine -127 to +127  Video output format setting Format 480i, 720pHorizontal phase can be adjusted when a genlock signal  SD 480i 2D LPF SD 2D LPF Off, Low, High Component output setting Component RGB, Y/Pb/Pr, Y/C Iris Control NGPage Menu item setting/changing User Mode Sub menu User Mode Brightness Set Display  HD Detail Set Display Color Correction Set Display  SD Detail Set Display Color Matrix Set Display  G/L Set Display  Other Set Display Detecting ratio adjustment Light PEAK/AVG P50 to A50  Black level setting Pedestal -150 to +150  Gain setting Gain Auto, -6 dB to 18 dB AGC maximum gain setting AGC Max Gain 6 dB, 12 dB, 18 dB  Color Set  Chroma level adjustment Chroma Level -3 to +3 Pedestal, B Pedestal Level dependent level setting Level Dependent 0 % to 25 %  Detail band setting Detail Band 1 to Noise suppress level setting Noise Suppress 1 to  Clean DNR setting Clean DNR Off, Low, High  Dark detail level setting Dark Detail 0 to Chroma detail level setting Chroma Detail 0 to  Level dependent level setting Level Dependent 0 % to 25 %  Detail band setting Detail Band 1 to Noise suppress level setting Noise Suppress 1 to  Clean DNR setting Clean DNR Off, Low, High  Dark detail level setting Dark Detail 0 to Chroma detail level setting Chroma Detail 0 to Linear Matrix R-B MatrixR-B -31 to +31 Linear Matrix G-R MatrixG-R -31 to +31Linear Matrix G-B MatrixG-B -31 to +31 Linear Matrix B-R MatrixB-R -31 to +31Color Correction Set  G/L Set  Horizontal phase adjustment H Phase -206 to +49  Subcarrier phase fine adjustment SC Fine -127 to +127 Other Set  Gamma level setting Gamma 0.35 to  Knee level setting Knee Point 88 % to 98 %, Dynamic Flare correction level setting Flare R/G/B 0 to  Black stretch setting Black Stretch Off, On EBU matrix setting EBU Matrix Set Off, On  Video output format setting Format 480i, 720p Component output setting Component RGB, Y/Pb/Pr, Y/C Menu item setting/changing User Mode Changing the settings Changing the format settingsChanging the component setting Setting the EBU matrix Setting to initial set Factory presets Setting to initial setInitial settings of the setting items Factory preset values  Halogen, Fluorescent, Outdoor ModeUser EBU Matrix Set Troubleshooting No powerUsing the controller Cannot operateLens Cannot displayMenus  Check that the unit and lens have been connected properlySettings Camera’s imagesAre not displayed or They are disturbedSomething is wrong With the coloringPictures Pictures are tooIndicators flash Fan Error isMultiple color bands Color bars are Displayed Controller’sAppearance Unit inch mmSpecifications Video output format setting Input/Output connectorsIndicator White balanceAllowable temperature ranges Dimensions W  H  DWeight Ambient operating humidityMemo Memo Eastern Zone