Chapter 7 Menu description tables
7-5-6 WHITE BALANCE MODE
Item/ |
|
| Variable | Remarks | |
Data storage | range | ||||
| |||||
|
|
|
|
| |
FILTER INH |
|
| ON | For selecting whether or not to keep the AWB | |
|
|
| OFF | memory (Ach, Bch) data for each filter. | |
|
|
|
| ON: The data is kept in the two Ach and Bch | |
|
|
|
| memories for each filter used. | |
C U | F | E |
| OFF: The data is kept for each filter. | |
|
|
| |||
SHOCKLESS AWB | OFF | For selecting ON | |||
|
|
| FAST | or OFF for SHOCKLESS AWB which ensures | |
|
|
| NORMAL | that the setting of the white balance switch to | |
|
|
| SLOW1 | PRST, A or B is not accompanied by a shock. | |
|
|
| SLOW2 | In addition, the switching time can be | |
C U F E | SLOW3 | selected. | |||
|
|
|
|
| |
AWB AREA |
|
| 25% | For selecting the AWB detection area. | |
|
|
| 50% | 25%: An area near the screen center | |
|
|
| 90% | equivalent to 25% of the screen is | |
|
|
|
| detected. | |
|
|
|
| 50%: An area near the screen center | |
|
|
|
| equivalent to 50% of the screen is | |
|
|
|
| detected. | |
|
|
|
| 90%: An area equivalent to 90% of the | |
C U | F | E |
| screen is detected. | |
|
|
|
|
| |
AWB & ABB |
|
| ON | For selecting whether or not to reset the GAIN | |
OFFSET |
|
| OFF | and PED values on the ROP menu when | |
|
|
|
| AWB or ABB is executed. | |
|
|
|
| ON: The values are not reset. | |
C U | F | E |
| OFF: The values are reset. | |
|
|
| |||
COLOR TEMP PRE | 3200K | For selecting the AWB PRE color | |||
|
|
| : | temperature. | |
C U | F | E | 5600K | ||
| |||||
|
|
|
|
| |
AWB A |
|
| MEM | For selecting the allocation of the WHITE BAL | |
|
|
| VAR | switch position and Ach. | |
|
|
|
| MEM: The switch position and Ach are | |
|
|
|
| allocated as memory values when | |
|
|
|
| AWB is executed. | |
|
|
|
| VAR: The color temperature of A can be set | |
|
|
|
| to vary using the COLOR TEMP A | |
C U | F | E |
| menu item. | |
|
|
|
| ||
COLOR TEMP A |
| 3200K | For setting the color temperature when AWB | ||
|
|
| : | A has been set to VAR. | |
C U | F | E | 5600K | ||
| |||||
|
|
|
|
| |
AWB B |
|
| MEM | For selecting the allocation of the WHITE BAL | |
|
|
| ATW | switch position and Bch. | |
|
|
| VAR | MEM: The switch position and Bch are | |
|
|
|
| allocated as memory values when | |
|
|
|
| AWB is executed. | |
|
|
|
| ATW: The position and Bch are allocated as | |
|
|
|
| ATW start switch functions. | |
|
|
|
| VAR: The color temperature of B can be set | |
|
|
|
| to vary using the COLOR TEMP B | |
C U | F | E |
| menu item. | |
|
|
|
| ||
COLOR TEMP B |
| 3200K | For setting the color temperature when AWB | ||
|
|
| : | B has been set to VAR. | |
C U | F | E | 5600K | ||
| |||||
|
|
|
|
| |
ATW SPEED |
|
| NORMAL | For selecting the ATW control speed. | |
|
|
| SLOW |
| |
C U | F | E | FAST |
| |
|
|
|
|
|
7-5-7 USER SW GAIN
Item/ |
|
|
|
| Variable |
| Remarks | |
Data storage |
|
|
| range |
| |||
|
|
|
|
| ||||
|
|
|
|
|
|
|
| |
S.GAIN |
|
| 2 |
|
| For selecting whether or not to enable a | ||
30 dB |
|
|
| O |
|
| setting of 30 dB for SUPER GAIN. | |
|
|
|
|
|
|
| 2 | : The 30 dB setting is enabled. |
C U | F | E |
|
|
|
| O : The 30 dB setting is disabled. | |
|
|
|
|
|
|
| ||
36 dB |
|
| 2 |
|
| For selecting whether or not to enable a | ||
|
|
|
| O |
|
| setting of 36 dB for SUPER GAIN. | |
|
|
|
|
|
|
| 2 | : The 36 dB setting is enabled. |
C U | F | E |
|
|
|
| O : The 36 dB setting is disabled. | |
|
|
|
|
|
|
| ||
42 dB |
|
| 2 |
|
| For selecting whether or not to enable a | ||
|
|
|
| O |
|
| setting of 42 dB for SUPER GAIN. | |
|
|
|
|
|
|
| 2 | : The 42 dB setting is enabled. |
C U | F | E |
|
|
|
| O : The 42 dB setting is disabled. | |
|
|
|
|
|
|
| ||
48 dB |
|
| 2 |
|
| For selecting whether or not to enable a | ||
|
|
|
| O |
|
| setting of 48 dB for SUPER GAIN. | |
|
|
|
|
|
|
| 2 | : The 48 dB setting is enabled. |
C U | F | E |
|
|
|
| O : The 48 dB setting is disabled. | |
|
|
|
|
|
|
| ||
DS.GAIN |
|
| 2 |
|
| For selecting whether or not to enable a | ||
6 dB: (1/25) |
|
| O |
|
| setting increase of 6 dB for DS.GAIN. | ||
|
|
|
|
|
|
| 2 | : The 6 dB setting increase is enabled. |
C U | F | E |
|
|
|
| O : The 6 dB setting increase is disabled. | |
|
|
|
|
|
| |||
12 dB: (1/12) |
| 2 |
|
| For selecting whether or not to enable a | |||
|
|
|
| O |
|
| setting increase of 12 dB for DS.GAIN. | |
|
|
|
|
|
|
| 2 | : The 12 dB setting increase is enabled. |
C U | F | E |
|
|
|
| O : The 12 dB setting increase is disabled. | |
|
|
|
|
|
| |||
20 dB: (1/5) |
| 2 |
|
| For selecting whether or not to enable a | |||
|
|
|
| O |
|
| setting increase of 20 dB for DS.GAIN. | |
|
|
|
|
|
|
| 2 | : The 20 dB setting increase is enabled. |
C U | F | E |
|
|
|
| O : The 20 dB setting increase is disabled. | |
|
|
|
|
|
|
|
|
|
7
The underlining in the variable range column indicates the setting in the preset mode.
95