Axis Communications Q1765-LE PT user manual Recordings, Recording List, Continuous Recording

Page 34

AXIS Q1765–LE PT Mount Network Camera

Recordings

Recordings

The Axis product can be configured to record video continuously or according to an action rule:

To start a continuous recording, see page 34.

To set up action rules, see page 31.

To access recordings, see Recording List on page 34.

To configure camera controlled storage, see Storage on page 44.

Recording List

Recorded videos are listed on the Recordings > List page. The list shows each recording’s start date and time, duration and the event that triggered the recording.

To play or download a recording, follow these steps:

1.Go to Recordings > List.

2.Use the filter to narrow the list of recordings. Enter the desired filter criteria and click Filter. Some filters may take a long time to complete.

3.Select the recording.

4.Click Play to play the recording, or click Download to download the recording.

Multiple recordings can be downloaded at the same time. Select the recordings and click Download. The downloaded file is a zip file containing a minimum of three files, of which the Matroska (mkv) files are the actual recordings. The recordings are time-stamped with the date and time they were downloaded (that is, not the date the recordings were made).

Note

To play recordings in Windows Media Player, AXIS Matroska File Splitter must be installed. AXIS Matroska File Splitter can be downloaded from www.axis.com/techsup/software

For detailed recording and video information, select a recording and click Properties.

To remove a recording, select the recording and click Remove.

Continuous Recording

The Axis product can be configured to continuously save video to a storage device. For information about storage devices, see Storage on page 44. To prevent the disk from becoming full, it is recommended to configure the disk to automatically remove old recordings.

If a new stream profile is selected while a recording is ongoing, the recording will be stopped and saved in the recording list and a new recording with the new stream profile will start. All previous continuous recordings will remain in the recording list until they are removed manually or through automatic removal of old recordings.

To start a continuous recording, follow these steps:

1.Go to Recordings > Continuous.

2.Select Enabled.

3.Select the type of storage device from the Storage list.

4.Select a Stream profile to use for continuous recordings.

5.Click Save to save and start the recording.

34

Image 34
Contents Axis Q1765-LE PT Mount Network Camera Liability About this documentLegal Considerations Intellectual Property RightsSupport Learn MoreTable of Contents Axis Q1765-LE PT Mount Network CameraFor technical specifications, see Connectors and ButtonsNetwork Connector RJ45 Ethernet connector with Power over Ethernet PoERS485/RS422 Connector LED IndicatorsPower Connector SD Card SlotAccess from the Internet Access the ProductAccess from a Browser Set the Root PasswordConfigure Capture Mode Set Power Line FrequencyPTZ Mode Live ViewAxis Media Control viewer toolbar Go to Setup EventsControls on the Live View Manual TriggerPTZ Controls Media Streams How to Stream H.264Axis Media Control AMC Alternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAxis Q1765-LE PT Mount Network Camera Set Up the Product Basic SetupVideo Stream Click Save to apply the new settingsVideo Pixel CounterStream Profiles 264Go to Setup Video Camera Settings Camera SettingsCapture Mode Image AppearanceWide Dynamic Range Exposure SettingsWhite Balance Shutter & GainBuilt-in IR Illuminations LEDs Date/Time Formats in the online help To enable overlaysOverlay Day/NightOverlay Image Go to Video Overlay ImageUse Overlay Text in an Action Rule Privacy MaskGo to Events Action Rules Viewer Settings Configure the Live ViewDefault Viewer for Browsers Browser Viewer DescriptionUser Defined Links PTZ Pan Tilt Zoom Preset PositionsGuard Tour Advanced Install PTZ DriverDevice Settings Control QueueAxis Q1765-LE PT Mount Network Camera Shock Detection Set Up Motion Detection WindowsDetectors Motion DetectionHigh level 100% Default valuesParameter Object Size History Sensitivity Description Medium level 50%Applications Install ApplicationGo to Setup Applications Application LicensesAxis Q1765-LE PT Mount Network Camera Add Recipients Set Up Action Rules Events Go to Events Action Rules and click AddCreate Schedules Set Up RecurrencesSet Up Email Recipients Go to Events Schedules and click AddAxis Q1765-LE PT Mount Network Camera Continuous Recording RecordingsRecording List Go to Recordings ListLanguages Security To log in again and be configured to use this functionalitySystem Options UsersCertificates Go to Setup System Options Security CertificatesIeee Go to System Options Security IeeeIPv4 Address Configuration Basic TCP/IP SettingsClick Install certificate and upload the certificate Date & TimeARP/Ping IPv6 Address ConfigurationAssign IP Address Using ARP/Ping Linux/Unix syntaxAdvanced TCP/IP Settings Link-Local IPv4 Address Select Use the host name to set the host name manuallyGo to System Options Security Https QoS Quality of Service Smtp emailRTP/H.264 UPnPTM can be disabled under System Options Network UPnPTMUPnPTM BonjourNetwork Share StorageSD Card To add a network shareCOM Port MaintenancePorts & Devices Port StatusSystem Overview SupportSupport Overview Logs & ReportsPlain Config Reset to Factory Default SettingsFile Upload Emergency Recovery Procedure TroubleshootingUpgrade the Firmware Check the FirmwareProduct cannot be accessed from a browser Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product is accessible locally but not externallyVideo Camera Settings Problems with streaming H.264Video and image problems, general Key framesRe-mount the storage device Storage and disk management problemsStorage disruption Reformat the SD card and then click MountTechnical Specifications Connectors Performance Considerations RS485/422 ConnectorRX pair for all modes combined RX/TX for 2-wire RS485 Function PinM1.8