System Options

File Upload

Files, for example webpages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload.

Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the selected user group (viewer, operator or administrator) for the uploaded file.

Plain Config

Plain Config is for advanced users with experience of Axis product configuration. Most parameters can be set and modified from this page.

To open Plain Config, go to System Options > Advanced > Plain Config . Axis Support does not provide assistance.

Reset to Factory Default Settings

Important

Reset to factory default should be used with caution. A reset to factory default will reset all settings, including the IP address, to the factory default values.

Note

The installation and management software tools are available on the CD supplied with the product and from the support pages on www.axis.com/techsup

To reset the product to the factory default settings:

1.Disconnect power from the product.

2.Press and hold the control button and reconnect power. See Hardware Overview on page 5 .

3.Keep the control button pressed for about 15–30 seconds until the status LED indicator flashes amber.

4.Release the control button. The process is complete when the status LED indicator turns green. The product has been reset to the factory default settings. If no DHCP server is available on the network, the default IP address is 192.168.0.90

5.Using the installation and management software tools, assign an IP address, set the password, and access the video stream. It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.

47

Image 47
Contents Axis Q1765-LE PT Mount Network Camera Intellectual Property Rights About this documentLegal Considerations LiabilityLearn More SupportAxis Q1765-LE PT Mount Network Camera Table of ContentsRJ45 Ethernet connector with Power over Ethernet PoE Connectors and ButtonsNetwork Connector For technical specifications, seeSD Card Slot LED IndicatorsPower Connector RS485/RS422 ConnectorSet the Root Password Access the ProductAccess from a Browser Access from the InternetLive View Set Power Line FrequencyPTZ Mode Configure Capture ModeManual Trigger Go to Setup EventsControls on the Live View Axis Media Control viewer toolbarPTZ Controls Axis Media Control AMC How to Stream H.264Media Streams QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamAxis Q1765-LE PT Mount Network Camera Basic Setup Set Up the ProductPixel Counter Click Save to apply the new settingsVideo Video Stream264 Stream ProfilesImage Appearance Camera SettingsCapture Mode Go to Setup Video Camera SettingsShutter & Gain Exposure SettingsWhite Balance Wide Dynamic RangeDay/Night Date/Time Formats in the online help To enable overlaysOverlay Built-in IR Illuminations LEDsGo to Video Overlay Image Overlay ImageGo to Events Action Rules Privacy MaskUse Overlay Text in an Action Rule Browser Viewer Description Configure the Live ViewDefault Viewer for Browsers Viewer SettingsUser Defined Links Guard Tour Preset PositionsPTZ Pan Tilt Zoom Control Queue Install PTZ DriverDevice Settings AdvancedAxis Q1765-LE PT Mount Network Camera Motion Detection Set Up Motion Detection WindowsDetectors Shock DetectionMedium level 50% Default valuesParameter Object Size History Sensitivity Description High level 100%Application Licenses Install ApplicationGo to Setup Applications ApplicationsAxis Q1765-LE PT Mount Network Camera Go to Events Action Rules and click Add Set Up Action RulesEvents Add RecipientsGo to Events Schedules and click Add Set Up RecurrencesSet Up Email Recipients Create SchedulesAxis Q1765-LE PT Mount Network Camera Go to Recordings List RecordingsRecording List Continuous RecordingLanguages Users To log in again and be configured to use this functionalitySystem Options SecurityGo to System Options Security Ieee Go to Setup System Options Security CertificatesIeee CertificatesDate & Time Basic TCP/IP SettingsClick Install certificate and upload the certificate IPv4 Address ConfigurationLinux/Unix syntax IPv6 Address ConfigurationAssign IP Address Using ARP/Ping ARP/PingAdvanced TCP/IP Settings Go to System Options Security Https Select Use the host name to set the host name manuallyLink-Local IPv4 Address Smtp email QoS Quality of ServiceBonjour UPnPTM can be disabled under System Options Network UPnPTMUPnPTM RTP/H.264To add a network share StorageSD Card Network SharePort Status MaintenancePorts & Devices COM PortLogs & Reports SupportSupport Overview System OverviewFile Upload Reset to Factory Default SettingsPlain Config Check the Firmware TroubleshootingUpgrade the Firmware Emergency Recovery ProcedureProduct is accessible locally but not externally Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserKey frames Problems with streaming H.264Video and image problems, general Video Camera SettingsReformat the SD card and then click Mount Storage and disk management problemsStorage disruption Re-mount the storage deviceTechnical Specifications Connectors Function Pin RS485/422 ConnectorRX pair for all modes combined RX/TX for 2-wire RS485 Performance ConsiderationsM1.8