Axis Communications Q1765-LE PT IPv6 Address Configuration, ARP/Ping, Linux/Unix syntax

Page 39

AXIS Q1765–LE PT Mount Network Camera

System Options

IPv6 Address Configuration

If IPv6 (IP version 6) is enabled, the Axis product will receive an IP address according to the configuration in the network router.

To enable IPv6, go to System Options > Network > TCP/IP > Basic. Other settings for IPv6 should be configured in the network router.

ARP/Ping

The product’s IP address can be assigned using ARP and Ping. For instructions, see Assign IP Address Using ARP/Ping on page 39.

The ARP/Ping service is enabled by default but is automatically disabled two minutes after the product is started, or as soon as an IP address is assigned. To re-assign IP address using ARP/Ping, the product must be restarted to enable ARP/Ping for an additional two minutes.

To disable the service, go to System Options > Network > TCP/IP > Basic and clear the option Enable ARP/Ping setting of IP address.

Pinging the product is still possible when the service is disabled.

Assign IP Address Using ARP/Ping

The product's IP address can be assigned using ARP/Ping. The command must be issued within 2 minutes of connecting power.

1.Acquire a free static IP address on the same network segment as the computer.

2.Locate the serial number (S/N) on the product label.

3.Open a command prompt and enter the following commands:

Linux/Unix syntax

arp -s <IP address> <serial number> temp ping -s 408 <IP address>

Linux/Unix example

arp -s 192.168.0.125 00:40:8c:18:10:00 temp ping -s 408 192.168.0.125

Windows syntax (this may require that you run the command prompt as an administrator)

arp -s <IP address> <serial number> ping -l 408 -t <IP address>

Windows example (this may require that you run the command prompt as an administrator)

arp -s 192.168.0.125 00-40-8c-18-10-00 ping -l 408 -t 192.168.0.125

4.Check that the network cable is connected and then restart the product by disconnecting and reconnecting power.

5.Close the command prompt when the product responds with Reply from 192.168.0.125:... or similar.

6.Open a browser and type http://<IP address> in the Location/Address field.

For other methods of assigning the IP address, see the Installation and Management Software CD or the document Assign an IP Address and Access the Video Stream on Axis Support web at www.axis.com/techsup

Note

To open a command prompt in Windows, open the Start menu and type cmd in the Run/Search field.

To use the ARP command in Windows 8/Windows 7/Windows Vista, right-click the command prompt icon and select Run as administrator.

To open a command prompt in Mac OS X, open the Terminal utility from Application > Utilities.

39

Image 39
Contents Axis Q1765-LE PT Mount Network Camera Intellectual Property Rights About this documentLegal Considerations LiabilityLearn More SupportAxis Q1765-LE PT Mount Network Camera Table of ContentsRJ45 Ethernet connector with Power over Ethernet PoE Connectors and ButtonsNetwork Connector For technical specifications, seeSD Card Slot LED IndicatorsPower Connector RS485/RS422 ConnectorSet the Root Password Access the ProductAccess from a Browser Access from the InternetLive View Set Power Line FrequencyPTZ Mode Configure Capture ModeManual Trigger Go to Setup EventsControls on the Live View Axis Media Control viewer toolbarPTZ Controls How to Stream H.264 Media StreamsAxis Media Control AMC QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamAxis Q1765-LE PT Mount Network Camera Basic Setup Set Up the ProductPixel Counter Click Save to apply the new settingsVideo Video Stream264 Stream ProfilesImage Appearance Camera SettingsCapture Mode Go to Setup Video Camera SettingsShutter & Gain Exposure SettingsWhite Balance Wide Dynamic RangeDay/Night Date/Time Formats in the online help To enable overlaysOverlay Built-in IR Illuminations LEDsGo to Video Overlay Image Overlay ImagePrivacy Mask Use Overlay Text in an Action RuleGo to Events Action Rules Browser Viewer Description Configure the Live ViewDefault Viewer for Browsers Viewer SettingsUser Defined Links Preset Positions PTZ Pan Tilt ZoomGuard Tour Control Queue Install PTZ DriverDevice Settings AdvancedAxis Q1765-LE PT Mount Network Camera Motion Detection Set Up Motion Detection WindowsDetectors Shock DetectionMedium level 50% Default valuesParameter Object Size History Sensitivity Description High level 100%Application Licenses Install ApplicationGo to Setup Applications ApplicationsAxis Q1765-LE PT Mount Network Camera Go to Events Action Rules and click Add Set Up Action RulesEvents Add RecipientsGo to Events Schedules and click Add Set Up RecurrencesSet Up Email Recipients Create SchedulesAxis Q1765-LE PT Mount Network Camera Go to Recordings List RecordingsRecording List Continuous RecordingLanguages Users To log in again and be configured to use this functionalitySystem Options SecurityGo to System Options Security Ieee Go to Setup System Options Security CertificatesIeee CertificatesDate & Time Basic TCP/IP SettingsClick Install certificate and upload the certificate IPv4 Address ConfigurationLinux/Unix syntax IPv6 Address ConfigurationAssign IP Address Using ARP/Ping ARP/PingAdvanced TCP/IP Settings Select Use the host name to set the host name manually Link-Local IPv4 AddressGo to System Options Security Https Smtp email QoS Quality of ServiceBonjour UPnPTM can be disabled under System Options Network UPnPTMUPnPTM RTP/H.264To add a network share StorageSD Card Network SharePort Status MaintenancePorts & Devices COM PortLogs & Reports SupportSupport Overview System OverviewReset to Factory Default Settings Plain ConfigFile Upload Check the Firmware TroubleshootingUpgrade the Firmware Emergency Recovery ProcedureProduct is accessible locally but not externally Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserKey frames Problems with streaming H.264Video and image problems, general Video Camera SettingsReformat the SD card and then click Mount Storage and disk management problemsStorage disruption Re-mount the storage deviceTechnical Specifications Connectors Function Pin RS485/422 ConnectorRX pair for all modes combined RX/TX for 2-wire RS485 Performance ConsiderationsM1.8