Axis Communications Q1765-LE PT user manual Configure the Live View, Default Viewer for Browsers

Page 22

AXIS Q1765–LE PT Mount Network Camera

Configure the Live View Page

Configure the Live View Page

You can customize the Live View page and alter it to suit your requirements. It is possible to define the following features of the Live View page.

Stream Profile. See page 16.

Default Viewer for Browser. See page 22.

Viewer Settings. See page 22.

Action Buttons. These are the buttons described in Controls on the Live View Page on page 9 .

User Defined Links. See page 23.

Default Viewer for Browsers

From Live View Config > Default Viewer select the default method for viewing video images in your browser. The product attempts to show the video images in the selected video format and viewer. If this is not possible, the product overrides the settings and selects the best available combination.

Browser

Viewer

Description

 

 

 

Windows Internet Explorer

AMC

Recommended viewer in Internet Explorer (H.264/Motion JPEG).

 

 

 

 

QuickTime

H.264.

 

 

 

 

Java applet

A slower imaging alternative to AMC (Motion JPEG). Requires one of the

 

 

following installed on the client:

 

 

• JVM (J2SE) 1.4.2 or higher.

 

 

• JRE (J2SE) 5.0 or higher.

 

 

 

 

Still image

Displays still images only. Click the Refresh button in your browser to view a

 

 

new image.

 

 

 

Other browsers

Server Push

Recommended viewer for other browsers (Motion JPEG).

 

 

 

 

QuickTime

H.264.

 

 

 

 

Java applet

A slower imaging alternative to Server Push (Motion JPEG only).

 

 

 

 

Still image

Displays still images only. Click the Refresh button in your browser to view a

 

 

new image.

 

 

 

For more information, please see the online help .

Viewer Settings

To configure options for the viewer, go to Live View Config > Viewer Settings.

Select Show viewer toolbar to display the AXIS Media Control (AMC) or the QuickTime viewer toolbar under the video image in your browser.

H.264 decoder installation. The administrator can disable installation of the H.264 decoder included with AXIS Media Control. This is used to prevent installation of unlicensed copies. Further decoder licenses can be purchased from your Axis reseller.

Select Enable recording button to enable recording from the Live View page. This button is available when using the AMC viewer. The recordings are saved to the location specified in the AMC Control Panel. See AXIS Media Control (AMC) on page 11 .

22

Image 22
Contents Axis Q1765-LE PT Mount Network Camera Liability About this documentLegal Considerations Intellectual Property RightsSupport Learn MoreTable of Contents Axis Q1765-LE PT Mount Network CameraFor technical specifications, see Connectors and ButtonsNetwork Connector RJ45 Ethernet connector with Power over Ethernet PoERS485/RS422 Connector LED IndicatorsPower Connector SD Card SlotAccess from the Internet Access the ProductAccess from a Browser Set the Root PasswordConfigure Capture Mode Set Power Line FrequencyPTZ Mode Live ViewAxis Media Control viewer toolbar Go to Setup EventsControls on the Live View Manual TriggerPTZ Controls Media Streams How to Stream H.264Axis Media Control AMC Alternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAxis Q1765-LE PT Mount Network Camera Set Up the Product Basic SetupVideo Stream Click Save to apply the new settingsVideo Pixel CounterStream Profiles 264Go to Setup Video Camera Settings Camera SettingsCapture Mode Image AppearanceWide Dynamic Range Exposure SettingsWhite Balance Shutter & GainBuilt-in IR Illuminations LEDs Date/Time Formats in the online help To enable overlaysOverlay Day/NightOverlay Image Go to Video Overlay ImageUse Overlay Text in an Action Rule Privacy MaskGo to Events Action Rules Viewer Settings Configure the Live ViewDefault Viewer for Browsers Browser Viewer DescriptionUser Defined Links PTZ Pan Tilt Zoom Preset PositionsGuard Tour Advanced Install PTZ DriverDevice Settings Control QueueAxis Q1765-LE PT Mount Network Camera Shock Detection Set Up Motion Detection WindowsDetectors Motion DetectionHigh level 100% Default valuesParameter Object Size History Sensitivity Description Medium level 50%Applications Install ApplicationGo to Setup Applications Application LicensesAxis Q1765-LE PT Mount Network Camera Add Recipients Set Up Action RulesEvents Go to Events Action Rules and click AddCreate Schedules Set Up RecurrencesSet Up Email Recipients Go to Events Schedules and click AddAxis Q1765-LE PT Mount Network Camera Continuous Recording RecordingsRecording List Go to Recordings ListLanguages Security To log in again and be configured to use this functionalitySystem Options UsersCertificates Go to Setup System Options Security CertificatesIeee Go to System Options Security IeeeIPv4 Address Configuration Basic TCP/IP SettingsClick Install certificate and upload the certificate Date & TimeARP/Ping IPv6 Address ConfigurationAssign IP Address Using ARP/Ping Linux/Unix syntaxAdvanced TCP/IP Settings Link-Local IPv4 Address Select Use the host name to set the host name manuallyGo to System Options Security Https QoS Quality of Service Smtp emailRTP/H.264 UPnPTM can be disabled under System Options Network UPnPTMUPnPTM BonjourNetwork Share StorageSD Card To add a network shareCOM Port MaintenancePorts & Devices Port StatusSystem Overview SupportSupport Overview Logs & ReportsPlain Config Reset to Factory Default SettingsFile Upload Emergency Recovery Procedure TroubleshootingUpgrade the Firmware Check the FirmwareProduct cannot be accessed from a browser Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product is accessible locally but not externallyVideo Camera Settings Problems with streaming H.264Video and image problems, general Key framesRe-mount the storage device Storage and disk management problemsStorage disruption Reformat the SD card and then click MountTechnical Specifications Connectors Performance Considerations RS485/422 ConnectorRX pair for all modes combined RX/TX for 2-wire RS485 Function PinM1.8