AXIS P5522 PTZ Dome Network Camera

System Options

Crash Report - Generates an archive with debugging information. The report takes several minutes to generate.

The log levels for the System Log and the Access Log are set under System Options > Support > Logs & Reports > Configuration . The Access Log can be configured to list all connections to the product (select Critical, Warnings & Info).

Advanced

Scripting

Scripting allows experienced users to customize and use their own scripts.

NOTICE

Improper use may cause unexpected behavior and loss of contact with the Axis product.

Axis strongly recommends that you do not use this function unless you understand the consequences. Axis Support does not provide assistance for problems with customized scripts.

To open the Script Editor, go to System Options > Advanced > Scripting. If a script causes problems, reset the product to its factory default settings, see page 55.

For more information, see www.axis.com/developer

File Upload

Files, for example webpages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload.

Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the selected user group (viewer, operator or administrator) for the uploaded file.

Plain Config

Plain Config is for advanced users with experience of Axis product configuration. Most parameters can be set and modified from this page.

To open Plain Config, go to System Options > Advanced > Plain Config . Axis Support does not provide assistance.

Reset to Factory Default Settings

Important

Reset to factory default should be used with caution. A reset to factory default will reset all settings, including the IP address, to the factory default values.

Note

The installation and management software tools are available on the CD supplied with the product and from the support pages on www.axis.com/techsup

To reset the product to the factory default settings:

1.Press and hold the control button and the restart button at the same time.

2.Release the restart button but continue to hold down the control button for about 15–30 seconds until the status LED indicator flashes amber.

3.Release the control button. The process is complete when the status LED indicator turns green. The product has been reset to the factory default settings. If no DHCP server is available on the network, the default IP address is 192.168.0.90

55

Image 55
Contents Axis P5522 PTZ Dome Network Camera Equipment Modifications About this document Legal ConsiderationsLiability Intellectual Property RightsLearn More SupportAxis P5522 PTZ Dome Network Camera Table of ContentsPerformance Considerations Support Advanced Reset to Factory Default SettingsHazard Levels Safety InformationOther Message Levels Hardware Overview For technical specifications, see Connectors and ButtonsNetwork Connector Multi-connectorControl Button LED IndicatorsMidspan LED Indicators SD Card SlotAccess from a Browser Access the ProductAccess from the Internet Controls on the Live View Set the Root PasswordSet Power Line Frequency Live ViewTo show the manual trigger buttons in the Live View Go to Setup EventsAxis Media Control viewer toolbar Manual TriggerAMC Audio Controls PTZ ControlsAxis P5522 PTZ Dome Network Camera Media Streams How to Stream H.264Axis Media Control AMC QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamJava applet supports simplex audio with G.711 encoding Access Audio StreamsBasic Setup Set Up the ProductImage Set Up Video StreamsVideo and Audio Pixel CounterStream Profiles Click Save to apply the new settings264 White Balance Camera SettingsExposure Settings Image AppearanceOverlay Image SettingsGo to Video & Audio Video Stream and select the Image tab Use Overlay Text in an Action Rule Overlay ImageGo to Video & Audio Overlay Image Go to Events Action Rules Set Up AudioPrivacy Mask Audio ModesAudio Input Audio Output Audio ClipsBrowser Viewer Description Configure the Live ViewDefault Viewer for Browsers Viewer SettingsUser Defined Links Go to Setup Live View ConfigOutput Buttons PTZ Pan Tilt Zoom Preset PositionsGatekeeper Limits Guard TourOsdi Zones AdvancedControls Control Queue Operator Same as administrator but with lower priorityMotion Detection Parameters Set Up Motion Detection WindowsDetectors Motion DetectionLow level 0% Default valuesAudio Detection Medium level 50%Application Licenses Install ApplicationGo to Setup Applications ApplicationsAxis P5522 PTZ Dome Network Camera Go to Events Action Rules and click Add Set Up Action RulesEvents Convert Event Types to Action RulesActions TriggersGo to Events Recipients and click Add Add RecipientsRecipient Types PTZ ControlCreate Schedules Set Up Email RecipientsGo to Events Schedules and click Add Go to Events Recurrences and click Add Set Up RecurrencesGo to Recordings List RecordingsRecording List Continuous RecordingLanguages IP Address Filter System OptionsSecurity UsersCertificates IeeeGo to System Options Security Ieee Audio Support Go to Setup System Options Security CertificatesClick Install certificate and upload the certificate Date & TimeNetwork Basic TCP/IP SettingsDNS Configuration Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service Axis Internet Dynamic DNS Service requires IPv4NAT traversal port mapping for IPv4 NTP ConfigurationHost Name Configuration Link-Local IPv4 AddressFTP QoS Quality of ServiceBonjour UPnPTM can be disabled under System Options Network UPnPTMUPnPTM RTP/H.264 Format SD Card Storage SD Card Mount and Unmount SD CardPorts MaintenancePorts & Devices Network ShareLogs & Reports SupportSupport Overview System OverviewFile Upload Reset to Factory Default SettingsPlain Config ScriptingAxis P5522 PTZ Dome Network Camera Drain, 100 mA Multi-Connector Cable sold separatelyCable provides the following connectors Function Pin SpecificationsConnector Check the Firmware TroubleshootingUpgrade the Firmware Emergency Recovery ProcedureProduct is accessible locally but not externally Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserKey frames Problems with streaming H.264Video and image problems, general Setup Video & Audio Camera SettingsPoor audio quality SettingsStorage and disk management problems No audioTechnical Specifications Power Function/group Specifications Network SecurityInstallation Maintenance General CasingPerformance Considerations M5.2