Bosch Appliances NBC-265-P Video resolution, 4CIF/D1, 720p, Expert Settings, GOP structure

Page 46

46 en Advanced Mode

IP Camera 200 Series

 

 

advantageous with low bandwidths. The image rate in ips (images per second) is displayed next to the slider.

Video resolution

Select the desired resolution for the video image. The following resolutions are available:

CIF

352 × 240 pixels

4CIF/D1

704 × 480 pixels

QVGA

320 x 240 pixels

VGA

640 × 480 pixels

720p

1280 × 720 pixels

Expert Settings

if necessary, use the expert settings to adapt the I-frame quality and the P-frame quality to specific requirements. The setting is based on the H.264 quantization parameter (QP).

GOP structure

Select the structure you require for the Group of Pictures. Depending on whether you place greater priority on having the lowest possible delay (IP frames only) or using as little bandwidth possible, you choose IP, IBP or IBBP.

I-frame distance

Use the slider to set the distance between I-frames to Auto or to between 3 and 60. An entry of 3 means that every third image is an I-frame.The lower the number, the more I-frames are generated.

I-frame quality

This setting sets the image quality of the I-frames. Select Auto to ensure that the maximum bit rate is not exceeded. Auto automatically changes the I-frame quality to the settings for the P-frame image quality.

AR18-10-B012 v1.5 2011.01

Installation and Operation Manual

Bosch Security Systems

Image 46
Contents IP Camera 200 Series Page Table of Contents Basic Mode Advanced ModeTroubleshooting Operation via the browserMaintenance Technical Data 101Safety Safety precautionsImportant safety instructions FCC & Ices compliance FCC & Ices InformationDisclaimer UL certificationBosch notices More informationCopyrights En Safety IP Camera 200 Series Features IntroductionUnpacking CD ROMInstallation SD cardMounting the camera Mounting a cameraIP Camera 200 Series Installation en Network and power connector Network connectionPower connection DC power connectionI/O connector Function Pin SocketAudio connectors Audio connectorsResetting the camera Reset buttonSystem requirements Browser connectionEstablishing the connection Password protection in camera Protected networkConnection established LivepageEn Browser connection IP Camera 200 Series Basic Mode menu tree Basic ModeSaving changes Password Device AccessPassword Camera nameDate/Time Confirm passwordDevice date, time and zone IP address Click Set and RebootNetwork Subnet maskRecording EncoderAudio System OverviewEn Basic Mode IP Camera 200 Series Advanced Mode Advanced Mode menu treeCamera ID GeneralIdentification Camera namePassword Device date / Device time Date/TimeDate format Device time zoneTime server type Display StampingTime server IP address Camera name stampingTime stamping Alarm mode stampingAlarm message Display millisecondsWebsite language Web InterfaceAppearance Company logoLivepage Functions Logging Picture Settings CameraDefault AR18-10-B012 v1.5 Target bit rate Profile ConfigurationProfile name Maximum bit rate4CIF/D1 Video resolutionExpert Settings 720pDefault Encoder Streams Audio Mirror image Installer MenuCamera LED Flip imageRecording Recording media Storage ManagementDevice manager ISCSI MediaActivating and Configuring Storage Media Formatting Storage Media Deactivating Storage MediaRecording includes Stream profile settingsRecording Profiles Standard recordingAlarm recording Retention Time Weekdays Recording SchedulerHolidays Activate recording Recording StatusProfile names Recording statusAlarm Alarm ConnectionsStream Select 10 in the Number of destination IP address list boxVideo transmission Remote portAuto-connect DecoderSSL encryption AudioVideo Content Analyses VCA VCA configuration- Profiles Aggregation time sMotion detector Analysis typeSensitivity Selecting the area Minimum object sizeDebounce time 1 s Tamper detectionGlobal change Trigger delay sGlobal change slider Scene too brightScene too noisy Scene too darkReference check Appearing edges VCA configuration Scheduled Deleting HolidaysIP Camera 200 Series Advanced Mode en Trigger VCA configuration Event triggeredDelay s Trigger activeSignal Ranges Audio AlarmAudio alarm NameAlarm E-Mail Sender name Destination addressTest e-mail Interfaces Alarm inputRelay Relay name Relay followsTrigger relay Network Access Automatic IP assignmentHttp browser port DNS server addressDetails Video transmission Https browser portRCP+ port Interface mode ETHEnable DynDNS Telnet supportForce registration now Host nameUser name StatusSnmp host address / 2. Snmp host address AuthenticationAdvanced Snmp trapsUPnP MulticastRtsp port TCP metadata inputPort EnableMulticast Address StreamingFTP Posting Maintenance ServiceFirmware Configuration SSL certificateMaintenance log System OverviewLivepage Operation via the browserProcessor load Image selection Digital I/O System Log / Event LogRunning recording program Saving snapshotsRecording video sequences Audio communicationIP Camera 200 Series Operation via the browser en Selecting Recordings RecordingsControlling playback Export to FTPSlide control BookmarksEn Operation via the browser IP Camera 200 Series Resolving problems TroubleshootingLED indicators Customer serviceEn Troubleshooting IP Camera 200 Series Repairs MaintenanceTransfer and disposal En Maintenance IP Camera 200 Series Technical Data SpecificationsEn Technical DataIP Camera 200 Series Dimensions AccessoriesEn Technical Data IP Camera 200 Series Page Bosch Security Systems