6.5.1Storage Management

Device manager

If the VRM option is activated, the VRM Video Recording Manager manages all recording and no further settings can be configured here.

Note:

Activating or deactivating VRM causes the current settings to be lost; they can only be restored through reconfiguration.

Recording media

Select the required recording media to activate them and then configure the recording parameters.

iSCSI Media

If an iSCSI system is selected as the storage medium, a connection to the desired iSCSI system is needed to set the configuration parameters.

The storage system selected must be available on the network and completely set up. Amongst other things, it must have an IP address and be divided into logical drives (LUN).

1.Enter the IP address of the required iSCSI destination in the iSCSI IP address field.

2.If the iSCSI destination is password protected, enter this into the Password field.

3.Click the Read button. The connection to the IP address is established. The Storage overview field displays the logical drives.

Local Media

The supported local recording media is displayed in the storage overview field.

SD card recording performance is highly dependent on the speed (class) and performance of the SD card. An SD card of Class 4 or higher is recommended.

AR18-10-B012 v1.5 2011.01

Installation and Operation Manual

Bosch Security Systems

Image 52
Contents IP Camera 200 Series Page Table of Contents Basic Mode Advanced ModeTroubleshooting Operation via the browserMaintenance Technical Data 101Safety Safety precautionsImportant safety instructions FCC & Ices compliance FCC & Ices InformationUL certification Bosch noticesDisclaimer More informationCopyrights En Safety IP Camera 200 Series Features IntroductionUnpacking CD ROMInstallation SD cardMounting the camera Mounting a cameraIP Camera 200 Series Installation en Network and power connector Network connectionPower connection DC power connectionI/O connector Function Pin SocketAudio connectors Audio connectorsResetting the camera Reset buttonSystem requirements Browser connectionEstablishing the connection Password protection in camera Protected networkConnection established LivepageEn Browser connection IP Camera 200 Series Basic Mode menu tree Basic ModeSaving changes Device Access PasswordPassword Camera nameDate/Time Confirm passwordDevice date, time and zone Click Set and Reboot NetworkIP address Subnet maskEncoder AudioRecording System OverviewEn Basic Mode IP Camera 200 Series Advanced Mode Advanced Mode menu treeGeneral IdentificationCamera ID Camera namePassword Date/Time Date formatDevice date / Device time Device time zoneDisplay Stamping Time server IP addressTime server type Camera name stampingAlarm mode stamping Alarm messageTime stamping Display millisecondsWeb Interface AppearanceWebsite language Company logoLivepage Functions Logging Picture Settings CameraDefault AR18-10-B012 v1.5 Profile Configuration Profile nameTarget bit rate Maximum bit rateVideo resolution Expert Settings4CIF/D1 720pDefault Encoder Streams Audio Installer Menu Camera LEDMirror image Flip imageRecording Storage Management Device managerRecording media ISCSI MediaActivating and Configuring Storage Media Formatting Storage Media Deactivating Storage MediaStream profile settings Recording ProfilesRecording includes Standard recordingAlarm recording Retention Time Weekdays Recording SchedulerHolidays Recording Status Profile namesActivate recording Recording statusAlarm Alarm ConnectionsSelect 10 in the Number of destination IP address list box Video transmissionStream Remote portDecoder SSL encryptionAuto-connect AudioVideo Content Analyses VCA VCA configuration- Profiles Aggregation time sMotion detector Analysis typeSensitivity Minimum object size Debounce time 1 sSelecting the area Tamper detectionTrigger delay s Global change sliderGlobal change Scene too brightScene too noisy Scene too darkReference check Appearing edges VCA configuration Scheduled Deleting HolidaysIP Camera 200 Series Advanced Mode en VCA configuration Event triggered Delay sTrigger Trigger activeAudio Alarm Audio alarmSignal Ranges NameAlarm E-Mail Sender name Destination addressTest e-mail Interfaces Alarm inputRelay Relay name Relay followsTrigger relay Network Access Automatic IP assignmentDNS server address Details Video transmissionHttp browser port Https browser portInterface mode ETH Enable DynDNSRCP+ port Telnet supportHost name User nameForce registration now StatusAuthentication AdvancedSnmp host address / 2. Snmp host address Snmp trapsMulticast Rtsp portUPnP TCP metadata inputEnable Multicast AddressPort StreamingFTP Posting Maintenance ServiceFirmware Configuration SSL certificateMaintenance log System OverviewLivepage Operation via the browserProcessor load Image selection Digital I/O System Log / Event LogSaving snapshots Recording video sequencesRunning recording program Audio communicationIP Camera 200 Series Operation via the browser en Recordings Controlling playbackSelecting Recordings Export to FTPSlide control BookmarksEn Operation via the browser IP Camera 200 Series Troubleshooting LED indicatorsResolving problems Customer serviceEn Troubleshooting IP Camera 200 Series Repairs MaintenanceTransfer and disposal En Maintenance IP Camera 200 Series Technical Data SpecificationsEn Technical DataIP Camera 200 Series Dimensions AccessoriesEn Technical Data IP Camera 200 Series Page Bosch Security Systems