Bosch Appliances NBC-265-P operation manual Appearing edges, Selecting the area

Page 69

IP Camera 200 Series

Advanced Mode en 69

 

 

Appearing edges

Select this option if the selected area of the reference image includes a largely homogenous surface. If structures appear in this area, then an alarm is triggered.

Selecting the area

Select the image areas in the reference image that are to be monitored. The video image is subdivided into square fields. Activate or deactivate each of these fields individually.

Select only those areas for reference monitoring in which no movement takes place and that are always evenly lit, as false alarms could otherwise be triggered.

1.Click Select Area to configure the sensor fields. A new window opens.

2.If necessary, click Clear All first to clear the current selection (fields marked yellow).

3.Left-click the fields to be activated. Activated fields are marked yellow.

4.If necessary, click Select All to select the entire video- frame for monitoring.

5.Right-click any fields to deactivate.

6.Click OK to save the configuration.

7.Click the close button (X) in the window title bar to close the window without saving the changes.

Bosch Security Systems

Installation and Operation Manual

AR18-10-B012 v1.5 2011.01

Image 69
Contents IP Camera 200 Series Page Table of Contents Advanced Mode Basic ModeOperation via the browser TroubleshootingTechnical Data 101 MaintenanceSafety precautions SafetyImportant safety instructions FCC & Ices Information FCC & Ices complianceBosch notices UL certificationDisclaimer More informationCopyrights En Safety IP Camera 200 Series Introduction FeaturesCD ROM UnpackingSD card InstallationMounting a camera Mounting the cameraIP Camera 200 Series Installation en Network connection Network and power connectorDC power connection Power connectionFunction Pin Socket I/O connectorAudio connectors Audio connectorsReset button Resetting the cameraBrowser connection System requirementsEstablishing the connection Protected network Password protection in cameraLivepage Connection establishedEn Browser connection IP Camera 200 Series Basic Mode Basic Mode menu treeSaving changes Password Device AccessPassword Camera nameConfirm password Date/TimeDevice date, time and zone Network Click Set and RebootIP address Subnet maskAudio EncoderRecording System OverviewEn Basic Mode IP Camera 200 Series Advanced Mode menu tree Advanced ModeIdentification GeneralCamera ID Camera namePassword Date format Date/TimeDevice date / Device time Device time zoneTime server IP address Display StampingTime server type Camera name stampingAlarm message Alarm mode stampingTime stamping Display millisecondsAppearance Web InterfaceWebsite language Company logoLivepage Functions Logging Camera Picture SettingsDefault AR18-10-B012 v1.5 Profile name Profile ConfigurationTarget bit rate Maximum bit rateExpert Settings Video resolution4CIF/D1 720pDefault Encoder Streams Audio Camera LED Installer MenuMirror image Flip imageRecording Device manager Storage ManagementRecording media ISCSI MediaActivating and Configuring Storage Media Deactivating Storage Media Formatting Storage MediaRecording Profiles Stream profile settingsRecording includes Standard recordingAlarm recording Retention Time Recording Scheduler WeekdaysHolidays Profile names Recording StatusActivate recording Recording statusAlarm Connections AlarmVideo transmission Select 10 in the Number of destination IP address list boxStream Remote portSSL encryption DecoderAuto-connect AudioVideo Content Analyses VCA Aggregation time s VCA configuration- ProfilesAnalysis type Motion detectorSensitivity Debounce time 1 s Minimum object sizeSelecting the area Tamper detectionGlobal change slider Trigger delay sGlobal change Scene too brightScene too dark Scene too noisyReference check Appearing edges Deleting Holidays VCA configuration ScheduledIP Camera 200 Series Advanced Mode en Delay s VCA configuration Event triggeredTrigger Trigger activeAudio alarm Audio AlarmSignal Ranges NameAlarm E-Mail Destination address Sender nameTest e-mail Alarm input InterfacesRelay Relay follows Relay nameTrigger relay Automatic IP assignment Network AccessDetails Video transmission DNS server addressHttp browser port Https browser portEnable DynDNS Interface mode ETHRCP+ port Telnet supportUser name Host nameForce registration now StatusAdvanced AuthenticationSnmp host address / 2. Snmp host address Snmp trapsRtsp port MulticastUPnP TCP metadata inputMulticast Address EnablePort StreamingFTP Posting Service MaintenanceFirmware SSL certificate ConfigurationSystem Overview Maintenance logOperation via the browser LivepageProcessor load Image selection System Log / Event Log Digital I/ORecording video sequences Saving snapshotsRunning recording program Audio communicationIP Camera 200 Series Operation via the browser en Controlling playback RecordingsSelecting Recordings Export to FTPBookmarks Slide controlEn Operation via the browser IP Camera 200 Series LED indicators TroubleshootingResolving problems Customer serviceEn Troubleshooting IP Camera 200 Series Maintenance RepairsTransfer and disposal En Maintenance IP Camera 200 Series Specifications Technical DataEn Technical DataIP Camera 200 Series Accessories DimensionsEn Technical Data IP Camera 200 Series Page Bosch Security Systems