Bosch Appliances NBC-265-P operation manual Activating and Configuring Storage Media

Page 53

IP Camera 200 Series

Advanced Mode en 53

 

 

Note:

If a device had primary and secondary recording running on the SD card and is then added to a VRM system, the blocks used for primary recording will not be re-used, reducing the available recording space for ANR recording. This can be solved by re- formatting the SD card.

Throughput limit for simultaneous recording and local replay at

100% playback speed is:

maximum total recording bit rate of 7 Mbps for external iSCSI recording.

maximum total recording bit rate of 10 Mbps for SD card recording, depending on SD card performance.

Activating and Configuring Storage Media

The storage overview displays the available storage media. Select individual media or iSCSI drives and transfer these to the Managed storage media list. Activate the storage media in this list and configure them for storage.

Note:

Each storage medium can only be associated with one user. If a storage medium is already being used by another user, decouple the user and connect the drive to the camera. Before decoupling, make absolutely sure that the previous user no longer needs the storage medium.

1.In the Recording media section, click the iSCSI Media or Local Media tab to display the applicable storage media in the overview.

2.In the Storage overview section, double-click the required storage medium, a SD card, an iSCSI LUN or one of the other available drives. The medium is then added to the Managed storage media list. Newly added media is indicated in the Status column by the status Not active.

3.Click Set to activate all media in the Managed storage media list. These are indicated in the Status column by the status Online.

Bosch Security Systems

Installation and Operation Manual

AR18-10-B012 v1.5 2011.01

Image 53
Contents IP Camera 200 Series Page Table of Contents Advanced Mode Basic ModeOperation via the browser TroubleshootingTechnical Data 101 MaintenanceSafety precautions SafetyImportant safety instructions FCC & Ices Information FCC & Ices complianceBosch notices UL certificationDisclaimer More informationCopyrights En Safety IP Camera 200 Series Introduction FeaturesCD ROM UnpackingSD card InstallationMounting a camera Mounting the cameraIP Camera 200 Series Installation en Network connection Network and power connectorDC power connection Power connectionFunction Pin Socket I/O connectorAudio connectors Audio connectorsReset button Resetting the cameraEstablishing the connection Browser connectionSystem requirements Protected network Password protection in cameraLivepage Connection establishedEn Browser connection IP Camera 200 Series Saving changes Basic ModeBasic Mode menu tree Password Device AccessPassword Camera nameDevice date, time and zone Confirm passwordDate/Time Network Click Set and RebootIP address Subnet maskAudio EncoderRecording System OverviewEn Basic Mode IP Camera 200 Series Advanced Mode menu tree Advanced ModeIdentification GeneralCamera ID Camera namePassword Date format Date/TimeDevice date / Device time Device time zoneTime server IP address Display StampingTime server type Camera name stampingAlarm message Alarm mode stampingTime stamping Display millisecondsAppearance Web InterfaceWebsite language Company logoLivepage Functions Logging Camera Picture SettingsDefault AR18-10-B012 v1.5 Profile name Profile ConfigurationTarget bit rate Maximum bit rateExpert Settings Video resolution4CIF/D1 720pDefault Encoder Streams Audio Camera LED Installer MenuMirror image Flip imageRecording Device manager Storage ManagementRecording media ISCSI MediaActivating and Configuring Storage Media Deactivating Storage Media Formatting Storage MediaRecording Profiles Stream profile settingsRecording includes Standard recordingAlarm recording Retention Time Holidays Recording SchedulerWeekdays Profile names Recording StatusActivate recording Recording statusAlarm Connections AlarmVideo transmission Select 10 in the Number of destination IP address list boxStream Remote portSSL encryption DecoderAuto-connect AudioVideo Content Analyses VCA Aggregation time s VCA configuration- ProfilesSensitivity Analysis typeMotion detector Debounce time 1 s Minimum object sizeSelecting the area Tamper detectionGlobal change slider Trigger delay sGlobal change Scene too brightReference check Scene too darkScene too noisy Appearing edges Deleting Holidays VCA configuration ScheduledIP Camera 200 Series Advanced Mode en Delay s VCA configuration Event triggeredTrigger Trigger activeAudio alarm Audio AlarmSignal Ranges NameAlarm E-Mail Test e-mail Destination addressSender name Relay Alarm inputInterfaces Trigger relay Relay followsRelay name Automatic IP assignment Network AccessDetails Video transmission DNS server addressHttp browser port Https browser portEnable DynDNS Interface mode ETHRCP+ port Telnet supportUser name Host nameForce registration now StatusAdvanced AuthenticationSnmp host address / 2. Snmp host address Snmp trapsRtsp port MulticastUPnP TCP metadata inputMulticast Address EnablePort StreamingFTP Posting Firmware ServiceMaintenance SSL certificate ConfigurationSystem Overview Maintenance logProcessor load Operation via the browserLivepage Image selection System Log / Event Log Digital I/ORecording video sequences Saving snapshotsRunning recording program Audio communicationIP Camera 200 Series Operation via the browser en Controlling playback RecordingsSelecting Recordings Export to FTPBookmarks Slide controlEn Operation via the browser IP Camera 200 Series LED indicators TroubleshootingResolving problems Customer serviceEn Troubleshooting IP Camera 200 Series Transfer and disposal MaintenanceRepairs En Maintenance IP Camera 200 Series Specifications Technical DataEn Technical DataIP Camera 200 Series Accessories DimensionsEn Technical Data IP Camera 200 Series Page Bosch Security Systems