Bosch Appliances NBC-265-P Profile Configuration, Profile name, Target bit rate, Maximum bit rate

Page 45

IP Camera 200 Series

Advanced Mode en 45

 

 

Profile Configuration

Profiles can be configured for use with the H.264 settings of encoder streams. Select a profile by clicking the appropriate tab. Change the name of a profile and individual parameter values within a profile.

Profiles are rather complex. They include a number of parameters that interact with one another, so it is generally best to use the default profiles. Only change a profile if completely familiar with all the configuration options.

The parameters as a group constitute a profile and are dependent on one another. If a setting outside the permitted range for a parameter is entered, the nearest valid value is substituted when the settings are saved.

Profile name

Enter a new name for the profile here.

Target bit rate

To optimize utilization of the bandwidth in the network, limit the bit rate for the camera. The target bit rate should be set according to the desired picture quality for typical scenes with no excessive motion.

For complex images or frequent changes of image content due to frequent movements, this limit can temporarily be exceeded up to the value entered in the Maximum bit rate field.

Maximum bit rate

This maximum bit rate is not exceeded under any circumstances. Depending on the video quality settings for the I-frames and P-frames, this can result in individual images being skipped.

The value entered here must be at least 10% higher than the value entered in the Target bit rate field. If the value entered here is too low, it is automatically adjusted.

Encoding interval

The Encoding interval slider determines the interval at which images are encoded and transmitted. This can be particularly

Bosch Security Systems

Installation and Operation Manual

AR18-10-B012 v1.5 2011.01

Image 45
Contents IP Camera 200 Series Page Table of Contents Advanced Mode Basic ModeOperation via the browser TroubleshootingTechnical Data 101 MaintenanceSafety precautions SafetyImportant safety instructions FCC & Ices Information FCC & Ices complianceBosch notices UL certificationDisclaimer More informationCopyrights En Safety IP Camera 200 Series Introduction FeaturesCD ROM UnpackingSD card InstallationMounting a camera Mounting the cameraIP Camera 200 Series Installation en Network connection Network and power connectorDC power connection Power connectionFunction Pin Socket I/O connectorAudio connectors Audio connectorsReset button Resetting the cameraBrowser connection System requirementsEstablishing the connection Protected network Password protection in cameraLivepage Connection establishedEn Browser connection IP Camera 200 Series Basic Mode Basic Mode menu treeSaving changes Password Device AccessPassword Camera nameConfirm password Date/TimeDevice date, time and zone Network Click Set and RebootIP address Subnet maskAudio EncoderRecording System OverviewEn Basic Mode IP Camera 200 Series Advanced Mode menu tree Advanced ModeIdentification GeneralCamera ID Camera namePassword Date format Date/TimeDevice date / Device time Device time zoneTime server IP address Display StampingTime server type Camera name stampingAlarm message Alarm mode stampingTime stamping Display millisecondsAppearance Web InterfaceWebsite language Company logoLivepage Functions Logging Camera Picture SettingsDefault AR18-10-B012 v1.5 Profile name Profile ConfigurationTarget bit rate Maximum bit rateExpert Settings Video resolution4CIF/D1 720pDefault Encoder Streams Audio Camera LED Installer MenuMirror image Flip imageRecording Device manager Storage ManagementRecording media ISCSI MediaActivating and Configuring Storage Media Deactivating Storage Media Formatting Storage MediaRecording Profiles Stream profile settingsRecording includes Standard recordingAlarm recording Retention Time Recording Scheduler WeekdaysHolidays Profile names Recording StatusActivate recording Recording statusAlarm Connections AlarmVideo transmission Select 10 in the Number of destination IP address list boxStream Remote portSSL encryption DecoderAuto-connect AudioVideo Content Analyses VCA Aggregation time s VCA configuration- ProfilesAnalysis type Motion detectorSensitivity Debounce time 1 s Minimum object sizeSelecting the area Tamper detectionGlobal change slider Trigger delay sGlobal change Scene too brightScene too dark Scene too noisyReference check Appearing edges Deleting Holidays VCA configuration ScheduledIP Camera 200 Series Advanced Mode en Delay s VCA configuration Event triggeredTrigger Trigger activeAudio alarm Audio AlarmSignal Ranges NameAlarm E-Mail Destination address Sender nameTest e-mail Alarm input InterfacesRelay Relay follows Relay nameTrigger relay Automatic IP assignment Network AccessDetails Video transmission DNS server addressHttp browser port Https browser portEnable DynDNS Interface mode ETHRCP+ port Telnet supportUser name Host nameForce registration now StatusAdvanced AuthenticationSnmp host address / 2. Snmp host address Snmp trapsRtsp port MulticastUPnP TCP metadata inputMulticast Address EnablePort StreamingFTP Posting Service MaintenanceFirmware SSL certificate ConfigurationSystem Overview Maintenance logOperation via the browser LivepageProcessor load Image selection System Log / Event Log Digital I/ORecording video sequences Saving snapshotsRunning recording program Audio communicationIP Camera 200 Series Operation via the browser en Controlling playback RecordingsSelecting Recordings Export to FTPBookmarks Slide controlEn Operation via the browser IP Camera 200 Series LED indicators TroubleshootingResolving problems Customer serviceEn Troubleshooting IP Camera 200 Series Maintenance RepairsTransfer and disposal En Maintenance IP Camera 200 Series Specifications Technical DataEn Technical DataIP Camera 200 Series Accessories DimensionsEn Technical Data IP Camera 200 Series Page Bosch Security Systems