Bosch Appliances NBC-265-P operation manual Network Access, Automatic IP assignment

Page 78

78 en Advanced Mode

IP Camera 200 Series

 

 

6.8Network

Network

>Network Access

>Advanced

>Multicast

>FTP Posting

6.8.1Network Access

The settings on this page are used to integrate the device into a network. Some changes only take effect after a reboot. In this case Set changes to Set and Reboot.

1.Make the desired changes.

2.Click Set and Reboot.

The device is rebooted and the changed settings are activated. If the IP address, subnet mask, or gateway address is changed, then the device is only available under the new addresses after the reboot.

Automatic IP assignment

If a DHCP server is employed in the network for the dynamic assignment of IP addresses, activate acceptance of IP addresses automatically assigned to the device.

Certain applications (Bosch Video Management System, Archive Player, Configuration Manager) use the IP address for the unique assignment of the device. If using these applications, the DHCP server must support the fixed assignment between IP address and MAC address, and must be appropriately set up so that, once an IP address is assigned, it is retained each time the system is rebooted.

IP address

Enter the desired IP address for the camera. The IP address must be valid for the network.

Subnet mask

Enter the appropriate subnet mask for the set IP address.

AR18-10-B012 v1.5 2011.01

Installation and Operation Manual

Bosch Security Systems

Image 78
Contents IP Camera 200 Series Page Table of Contents Basic Mode Advanced ModeTroubleshooting Operation via the browserMaintenance Technical Data 101Safety Safety precautionsImportant safety instructions FCC & Ices compliance FCC & Ices InformationDisclaimer UL certificationBosch notices More informationCopyrights En Safety IP Camera 200 Series Features IntroductionUnpacking CD ROMInstallation SD cardMounting the camera Mounting a cameraIP Camera 200 Series Installation en Network and power connector Network connectionPower connection DC power connectionI/O connector Function Pin SocketAudio connectors Audio connectorsResetting the camera Reset buttonBrowser connection System requirementsEstablishing the connection Password protection in camera Protected networkConnection established LivepageEn Browser connection IP Camera 200 Series Basic Mode Basic Mode menu treeSaving changes Password Device AccessPassword Camera nameConfirm password Date/TimeDevice date, time and zone IP address Click Set and RebootNetwork Subnet maskRecording EncoderAudio System OverviewEn Basic Mode IP Camera 200 Series Advanced Mode Advanced Mode menu treeCamera ID GeneralIdentification Camera namePassword Device date / Device time Date/TimeDate format Device time zoneTime server type Display StampingTime server IP address Camera name stampingTime stamping Alarm mode stampingAlarm message Display millisecondsWebsite language Web InterfaceAppearance Company logoLivepage Functions Logging Picture Settings CameraDefault AR18-10-B012 v1.5 Target bit rate Profile ConfigurationProfile name Maximum bit rate4CIF/D1 Video resolutionExpert Settings 720pDefault Encoder Streams Audio Mirror image Installer MenuCamera LED Flip imageRecording Recording media Storage ManagementDevice manager ISCSI MediaActivating and Configuring Storage Media Formatting Storage Media Deactivating Storage MediaRecording includes Stream profile settingsRecording Profiles Standard recordingAlarm recording Retention Time Recording Scheduler WeekdaysHolidays Activate recording Recording StatusProfile names Recording statusAlarm Alarm ConnectionsStream Select 10 in the Number of destination IP address list boxVideo transmission Remote portAuto-connect DecoderSSL encryption AudioVideo Content Analyses VCA VCA configuration- Profiles Aggregation time sAnalysis type Motion detectorSensitivity Selecting the area Minimum object sizeDebounce time 1 s Tamper detectionGlobal change Trigger delay sGlobal change slider Scene too brightScene too dark Scene too noisyReference check Appearing edges VCA configuration Scheduled Deleting HolidaysIP Camera 200 Series Advanced Mode en Trigger VCA configuration Event triggeredDelay s Trigger activeSignal Ranges Audio AlarmAudio alarm NameAlarm E-Mail Destination address Sender nameTest e-mail Alarm input InterfacesRelay Relay follows Relay nameTrigger relay Network Access Automatic IP assignmentHttp browser port DNS server addressDetails Video transmission Https browser portRCP+ port Interface mode ETHEnable DynDNS Telnet supportForce registration now Host nameUser name StatusSnmp host address / 2. Snmp host address AuthenticationAdvanced Snmp trapsUPnP MulticastRtsp port TCP metadata inputPort EnableMulticast Address StreamingFTP Posting Service MaintenanceFirmware Configuration SSL certificateMaintenance log System OverviewOperation via the browser LivepageProcessor load Image selection Digital I/O System Log / Event LogRunning recording program Saving snapshotsRecording video sequences Audio communicationIP Camera 200 Series Operation via the browser en Selecting Recordings RecordingsControlling playback Export to FTPSlide control BookmarksEn Operation via the browser IP Camera 200 Series Resolving problems TroubleshootingLED indicators Customer serviceEn Troubleshooting IP Camera 200 Series Maintenance RepairsTransfer and disposal En Maintenance IP Camera 200 Series Technical Data SpecificationsEn Technical DataIP Camera 200 Series Dimensions AccessoriesEn Technical Data IP Camera 200 Series Page Bosch Security Systems