Bosch Appliances NBC-265-P operation manual Encoder Streams

Page 48

48 en Advanced Mode

IP Camera 200 Series

 

 

6.4.3Encoder Streams

Select H.264 Settings

1.The codec algorithm for stream 1 is always:

H.264 MP 720p25/30 fixed

2.Select the codec algorithm for stream 2. The following are available:

Copy Stream 1

H.264 BP+ bit-rate-limited

H.264 MP SD

3.Select the default profile for each stream from the eight profiles that have been defined.

Preview >>

Previews of streams 1 and 2 can be shown.

1.Click Preview >> to display a preview of the video for streams 1 and 2. the current profile is shown above the preview.

2.Click 1:1 Live View below a preview to open a viewing window for that stream. Various additional items of information are shown across the top of the window.

3.Click Preview << to close the preview displays.

Note:

Deactivate the display of the video images if the performance of the computer is adversely affected by the decoding of the data stream.

JPEG stream

Set the parmeters for the M-JPEG stream.

Select the Max. frame rate in images per second (IPS).

The Picture quality slider allows adjustment of the M-JPEG image quality from Low to High.

Note:

The M-JPEG resolution follows the highest resolution setting of either stream 1 or stream 2. For example, if stream 1 is VGA and stream 2 is QVGA, the JPEG resolution will be VGA. The M-JPEG frame rate varies depending on system loading.

AR18-10-B012 v1.5 2011.01

Installation and Operation Manual

Bosch Security Systems

Image 48
Contents IP Camera 200 Series Page Table of Contents Basic Mode Advanced ModeTroubleshooting Operation via the browserMaintenance Technical Data 101Safety Safety precautionsImportant safety instructions FCC & Ices compliance FCC & Ices InformationUL certification Bosch noticesDisclaimer More informationCopyrights En Safety IP Camera 200 Series Features IntroductionUnpacking CD ROMInstallation SD cardMounting the camera Mounting a cameraIP Camera 200 Series Installation en Network and power connector Network connectionPower connection DC power connectionI/O connector Function Pin SocketAudio connectors Audio connectorsResetting the camera Reset buttonBrowser connection System requirementsEstablishing the connection Password protection in camera Protected networkConnection established LivepageEn Browser connection IP Camera 200 Series Basic Mode Basic Mode menu treeSaving changes Device Access PasswordPassword Camera nameConfirm password Date/TimeDevice date, time and zone Click Set and Reboot NetworkIP address Subnet maskEncoder AudioRecording System OverviewEn Basic Mode IP Camera 200 Series Advanced Mode Advanced Mode menu treeGeneral IdentificationCamera ID Camera namePassword Date/Time Date formatDevice date / Device time Device time zoneDisplay Stamping Time server IP addressTime server type Camera name stampingAlarm mode stamping Alarm messageTime stamping Display millisecondsWeb Interface AppearanceWebsite language Company logoLivepage Functions Logging Picture Settings CameraDefault AR18-10-B012 v1.5 Profile Configuration Profile nameTarget bit rate Maximum bit rateVideo resolution Expert Settings4CIF/D1 720pDefault Encoder Streams Audio Installer Menu Camera LEDMirror image Flip imageRecording Storage Management Device managerRecording media ISCSI MediaActivating and Configuring Storage Media Formatting Storage Media Deactivating Storage MediaStream profile settings Recording ProfilesRecording includes Standard recordingAlarm recording Retention Time Recording Scheduler WeekdaysHolidays Recording Status Profile namesActivate recording Recording statusAlarm Alarm ConnectionsSelect 10 in the Number of destination IP address list box Video transmissionStream Remote portDecoder SSL encryptionAuto-connect AudioVideo Content Analyses VCA VCA configuration- Profiles Aggregation time sAnalysis type Motion detectorSensitivity Minimum object size Debounce time 1 sSelecting the area Tamper detectionTrigger delay s Global change sliderGlobal change Scene too brightScene too dark Scene too noisyReference check Appearing edges VCA configuration Scheduled Deleting HolidaysIP Camera 200 Series Advanced Mode en VCA configuration Event triggered Delay sTrigger Trigger activeAudio Alarm Audio alarmSignal Ranges NameAlarm E-Mail Destination address Sender nameTest e-mail Alarm input InterfacesRelay Relay follows Relay nameTrigger relay Network Access Automatic IP assignmentDNS server address Details Video transmissionHttp browser port Https browser portInterface mode ETH Enable DynDNSRCP+ port Telnet supportHost name User nameForce registration now StatusAuthentication AdvancedSnmp host address / 2. Snmp host address Snmp trapsMulticast Rtsp portUPnP TCP metadata inputEnable Multicast AddressPort StreamingFTP Posting Service MaintenanceFirmware Configuration SSL certificateMaintenance log System OverviewOperation via the browser LivepageProcessor load Image selection Digital I/O System Log / Event LogSaving snapshots Recording video sequencesRunning recording program Audio communicationIP Camera 200 Series Operation via the browser en Recordings Controlling playbackSelecting Recordings Export to FTPSlide control BookmarksEn Operation via the browser IP Camera 200 Series Troubleshooting LED indicatorsResolving problems Customer serviceEn Troubleshooting IP Camera 200 Series Maintenance RepairsTransfer and disposal En Maintenance IP Camera 200 Series Technical Data SpecificationsEn Technical DataIP Camera 200 Series Dimensions AccessoriesEn Technical Data IP Camera 200 Series Page Bosch Security Systems