Advanced Mode en 55

 

 

6.5.2Recording Profiles

Define up to ten different recording profiles here, then assign these to individual days or times of day on the Recording Scheduler page. Modify the names of the recording profiles on the tabs in the Recording Scheduler page.

1.Click a tab to edit the corresponding profile.

2.If necessary, click Default to return all settings to their defaults.

3.Click Copy Settings to copy the currently visible settings to other profiles. A window opens to select the target profiles for the copied settings.

4.For each profile, click Set to save.

Stream profile settings

Select the profile setting that is to be used for each data stream when recording. This selection is independent of the selection for live data stream transmission. (The properties of the profiles are defined on the Encoder Profile page.)

Recording includes

Specify whether, in addition to video data, audio or metadata (for example alarms or VCA data) should also be recorded. Including metadata could make subsequent searches of recordings easier but it requires additional memory capacity. Without metadata, it is not possible to include video content analysis in recordings.

Standard recording

Select the mode for standard recordings:

Continuous: the recording proceeds continuously. If the maximum memory capacity is reached, older recordings will automatically be overwritten.

Pre-alarm: recording takes place in the pre-alarm time, during the alarm and during the post-alarm time only.

Off: no automatic recording takes place.

In the Stream list box, select Stream 1, Stream 2 or I-frames only for standard recordings.

Bosch Security Systems

Installation and Operation Manual

AR18-10-B012 v1.5 2011.01

Image 55
Contents IP Camera 200 Series Page Table of Contents Advanced Mode Basic ModeOperation via the browser TroubleshootingTechnical Data 101 MaintenanceSafety precautions SafetyImportant safety instructions FCC & Ices Information FCC & Ices complianceMore information UL certificationBosch notices DisclaimerCopyrights En Safety IP Camera 200 Series Introduction FeaturesCD ROM UnpackingSD card InstallationMounting a camera Mounting the cameraIP Camera 200 Series Installation en Network connection Network and power connectorDC power connection Power connectionFunction Pin Socket I/O connectorAudio connectors Audio connectorsReset button Resetting the cameraSystem requirements Browser connectionEstablishing the connection Protected network Password protection in cameraLivepage Connection establishedEn Browser connection IP Camera 200 Series Basic Mode menu tree Basic ModeSaving changes Camera name Device AccessPassword PasswordDate/Time Confirm passwordDevice date, time and zone Subnet mask Click Set and RebootNetwork IP addressSystem Overview EncoderAudio RecordingEn Basic Mode IP Camera 200 Series Advanced Mode menu tree Advanced ModeCamera name GeneralIdentification Camera IDPassword Device time zone Date/TimeDate format Device date / Device timeCamera name stamping Display StampingTime server IP address Time server typeDisplay milliseconds Alarm mode stampingAlarm message Time stampingCompany logo Web InterfaceAppearance Website languageLivepage Functions Logging Camera Picture SettingsDefault AR18-10-B012 v1.5 Maximum bit rate Profile ConfigurationProfile name Target bit rate720p Video resolutionExpert Settings 4CIF/D1Default Encoder Streams Audio Flip image Installer MenuCamera LED Mirror imageRecording ISCSI Media Storage ManagementDevice manager Recording mediaActivating and Configuring Storage Media Deactivating Storage Media Formatting Storage MediaStandard recording Stream profile settingsRecording Profiles Recording includesAlarm recording Retention Time Weekdays Recording SchedulerHolidays Recording status Recording StatusProfile names Activate recordingAlarm Connections AlarmRemote port Select 10 in the Number of destination IP address list boxVideo transmission StreamAudio DecoderSSL encryption Auto-connectVideo Content Analyses VCA Aggregation time s VCA configuration- ProfilesMotion detector Analysis typeSensitivity Tamper detection Minimum object sizeDebounce time 1 s Selecting the areaScene too bright Trigger delay sGlobal change slider Global changeScene too noisy Scene too darkReference check Appearing edges Deleting Holidays VCA configuration ScheduledIP Camera 200 Series Advanced Mode en Trigger active VCA configuration Event triggeredDelay s TriggerName Audio AlarmAudio alarm Signal RangesAlarm E-Mail Sender name Destination addressTest e-mail Interfaces Alarm inputRelay Relay name Relay followsTrigger relay Automatic IP assignment Network AccessHttps browser port DNS server addressDetails Video transmission Http browser portTelnet support Interface mode ETHEnable DynDNS RCP+ portStatus Host nameUser name Force registration nowSnmp traps AuthenticationAdvanced Snmp host address / 2. Snmp host addressTCP metadata input MulticastRtsp port UPnPStreaming EnableMulticast Address PortFTP Posting Maintenance ServiceFirmware SSL certificate ConfigurationSystem Overview Maintenance logLivepage Operation via the browserProcessor load Image selection System Log / Event Log Digital I/OAudio communication Saving snapshotsRecording video sequences Running recording programIP Camera 200 Series Operation via the browser en Export to FTP RecordingsControlling playback Selecting RecordingsBookmarks Slide controlEn Operation via the browser IP Camera 200 Series Customer service TroubleshootingLED indicators Resolving problemsEn Troubleshooting IP Camera 200 Series Repairs MaintenanceTransfer and disposal En Maintenance IP Camera 200 Series Specifications Technical DataEn Technical DataIP Camera 200 Series Accessories DimensionsEn Technical Data IP Camera 200 Series Page Bosch Security Systems