AXIS P3384–V Fixed Dome Network Camera

System Options

For more information, see www.axis.com/developer

File Upload

Files, for example webpages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload.

Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the selected user group (viewer, operator or administrator) for the uploaded file.

Plain Config

Plain Config is for advanced users with experience of Axis product configuration. Most parameters can be set and modified from this page.

To open Plain Config, go to System Options > Advanced > Plain Config . Axis Support does not provide assistance.

Reset to Factory Default Settings

Important

Reset to factory default should be used with caution. A reset to factory default will reset all settings, including the IP address, to the factory default values.

Note

The installation and management software tools are available on the CD supplied with the product and from the support pages on www.axis.com/techsup

To reset the product to the factory default settings:

1.Disconnect power from the product.

2.Press and hold the control button and reconnect power. See Hardware Overview on page 6 .

3.Keep the control button pressed for about 15–30 seconds until the status LED indicator flashes amber.

4.Release the control button. The process is complete when the status LED indicator turns green. The product has been reset to the factory default settings. If no DHCP server is available on the network, the default IP address is 192.168.0.90

5.Using the installation and management software tools, assign an IP address, set the password, and access the video stream. It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.

56

Image 56
Contents Axis P3384-V Fixed Dome Network Camera About this Document Legal ConsiderationsLiability Intellectual Property RightsSupport Learn MoreTable of Contents Axis P3384-V Fixed Dome Network CameraReset to Factory Default Settings Connectors Performance ConsiderationsConnectors and Buttons Network ConnectorConnector Hardware OverviewLED Indicators Audio ConnectorSD Card Slot Control ButtonAccess the Product Access from a BrowserAccess from the Internet Set the Root PasswordSet Power Line Frequency Live ViewControls on the Live View Click Use HttpsGo to Setup Events Axis Media Control viewer toolbarManual Trigger To show the manual trigger buttons in the Live ViewPTZ Controls AMC Audio ControlsAxis P3384-V Fixed Dome Network Camera Axis Media Control AMC How to Stream H.264Media Streams Alternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAccess Audio Streams Java applet supports simplex audio with G.711 encodingSet Up the Product Basic SetupClick Save to apply the new settings Video and AudioVideo Stream ImageStream Profiles MjpegCamera Settings Lightfinder ModeImage Appearance White BalanceExposure Settings Iris adjustmentShutter & Gain Set Shutter toSelect an Aspect ratio and a Video stream resolution View AreaOverlay Go to Video & Audio View AreaGo to Video & Audio Overlay Image Privacy MaskOverlay Image Audio Settings When satisfied, click Enable iris to enable the irisFocus & Zoom Audio ModesAudio Input Audio OutputAudio Clips Configure the Live View Default Viewer for BrowsersViewer Settings Browser Viewer DescriptionGo to Setup Live View Config User Defined LinksOutput Buttons For more information about I/O ports, see I/O Ports onPreset Positions PTZ Pan Tilt ZoomGuard Tour AdvancedOperator Same as administrator but with lower priority Control QueueDetectors Camera TamperingMotion Detection Go to Detectors Camera TamperingSet Up Motion Detection Windows Motion Detection ParametersAudio Detection Go to Detectors Audio DetectionInstall Application Go to Setup ApplicationsApplications Application LicensesAxis P3384-V Fixed Dome Network Camera Set Up Action Rules EventsTriggers Go to Events Action Rules and click AddInput Signal HardwareStorage SystemAdd Recipients ActionsRecipient Types PTZ ControlRecipient Use with action Set Up Email RecipientsCreate Schedules Go to Events Recurrences and click Add Set Up RecurrencesGo to Events Schedules and click Add Recordings Find RecordingsPlay Recording Go to Recordings ListExport Video Clip Recording ListContinuous Recording Go to Recordings ContinuousLanguages System Options SecurityUsers IP Address FilterCA Certificate IeeeCertificates Go to Setup System Options Security Certificates Click Install certificate and upload the certificateDate & Time CertificatesBasic TCP/IP Settings NetworkAxis Internet Dynamic DNS Service Linux/Unix syntaxLinux/Unix example Axis Video Hosting System AvhsAdvanced TCP/IP Settings DNS ConfigurationNTP Configuration Host Name ConfigurationHttps NAT traversal port mapping for IPv4QoS Quality of Service SocksStorage UPnPTMRTP/H.264 Bonjour Network Share Mount and Unmount SD Card Format SD Card To add a network shareMaintenance Ports & DevicesPorts Port StatusSupport Support OverviewSystem Overview Logs & ReportsFile Upload Reset to Factory Default SettingsPlain Config Troubleshooting Upgrade the FirmwareFirmware To upgrade the product’s firmware Check the FirmwareEmergency Recovery Procedure Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserBasic Product is accessible locally but not externallyProblems with streaming H.264 Status and Network indicator LEDs are flashing red rapidly Video and image problems, generalSetup Video & Audio Camera Settings SettingsVideo cannot be recorded Technical Specifications Function/group Specifications Network Security InstallationMaintenance SupportedFunction/group Specifications General Casing PowerConnectors DimensionsConnectors Function Pin SpecificationsAudio Output Performance ConsiderationsAudio Input M2.13