AXIS M5013 PTZ Dome Network Camera
System Options
For more information, see www.axis.com/developer
File Upload
Files, for example web pages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload.
Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the selected user group (viewer, operator or administrator) for the uploaded file.
Plain Config
Plain Config is for advanced users with experience of Axis product configuration. Most parameters can be set and modified from this page. Help is available from the standard help pages.
To open Plain Config, go to System Options > Advanced > Plain Config.
Reset to factory default settings
This will reset all parameters, including the IP address, to the factory default settings:
1.Disconnect power from the product.
2.Press and hold the Control button and reconnect power (see Hardware overview, on page 4 ).
3.Keep the Control button pressed for about 15 seconds until the Status indicator flashes amber.
4.Release the Control button. The process is complete after about 1 minute (when the Status indicator turns green). The product has been reset to the factory default settings. The default IP address is 192.168.0.90
5.
It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.
41