Axis Communications M3114-R user manual Reset to Factory Default Settings, Scripting, File Upload

Page 41

AXIS M3114-R Network Camera

System Options

Parameter List - Shows the product's parameters and their current settings. This may prove useful when troubleshooting or when contacting Axis Support.

Connection List - Lists all clients that are currently accessing media streams.

Crash Report - Generates an archive with debugging information. The report takes several minutes to generate.

The log levels for the System Log and the Access Log are set under System Options > Support > Logs & Reports > Configuration. The Access Log can be configured to list all connections to the product (select Critical, Warnings & Info).

Advanced

Scripting

Scripting allows experienced users to customize and use their own scripts.

NOTICE

Improper use may cause unexpected behavior and loss of contact with the Axis product.

Axis strongly recommends that you do not use this function unless you understand the consequences. Axis Support does not provide assistance for problems with customized scripts.

To open the Script Editor, go to System Options > Advanced > Scripting. If a script causes problems, reset the product to its factory default settings, see page 41.

For more information, see www.axis.com/developer

File Upload

Files, for example web pages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload.

Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the selected user group (viewer, operator or administrator) for the uploaded file.

Plain Config

Plain Config is for advanced users with experience of Axis product configuration. Most parameters can be set and modified from this page. Help is available from the standard help pages.

To open Plain Config, go to System Options > Advanced > Plain Config. Axis Support does not provide assistance.

Reset to Factory Default Settings

This will reset all parameters, including the IP address, to the factory default settings:

1.Disconnect power from the product.

2.Press and hold the Control button and reconnect power (see Hardware Overview, on page 4 ).

3.Keep the Control button pressed for about 15 seconds until the Status indicator flashes amber.

4.Release the Control button. The process is complete after about 1 minute (when the Status indicator turns green). The product has been reset to the factory default settings. The default IP address is 192.168.0.90

5.Re-assign the IP address.

It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.

41

Image 41
Contents Axis M3114-R Network Camera Liability About this documentIntellectual Property Rights Equipment ModificationsAxis M3114-R Network Camera Table of ContentsHardware Overview ConnectorsHardware Overview Color Indication LED IndicatorsAccess from a Browser Accessing the ProductAccessing the Product Set the Root Password Accessing the Product Access from the InternetNetwork TCP/IP Advanced Click Create self-signed certificateControls on the Live View Set Power Line FrequencyLive View PTZ Controls Axis Media Control viewer toolbarAxis M3114-R Network Camera Media Streams How to Stream H.264Media Streams Axis Media Control AMCAlternative Methods of Accessing the Video Stream Axis M3114-R Network Camera Basic Setup Setting Up the ProductSetting Up the Product Video VideoVideo Stream Pixel Counter264 Stream ProfilesImage Exposure Settings Camera SettingsImage Appearance White BalanceOverlay Video View AreaOverlay Image Go to Video Video Stream and select the Image tabGo to Video Overlay Image Privacy MaskDefault Viewer for Browsers Live View ConfigLive View Config Browser Viewer Description Viewer SettingsUser Defined Links PTZ Pan Tilt Zoom Preset PositionsPTZ Pan Tilt Zoom Guard TourControls AdvancedDetectors DetectorsCamera Tampering Motion DetectionMotion Detection Parameters Set Up Motion Detection WindowsRecommended values Default valuesLow level 0% Applications ApplicationsEvents EventsConvert Event Types to Action Rules Setting Up an Action RuleRecipients Go to Events Action Rules and click AddRecurrences SchedulesAxis M3114-R Network Camera Recordings RecordingsRecording List Continuous RecordingSystem Options System OptionsSecurity UsersCertificates Date & TimeIeee Network Basic TCP/IP SettingsAdvanced TCP/IP Settings NAT traversal port mapping for IPv4 Http Smtp email QoS Quality of ServiceUPnPTM StorageRTP/H.264 BonjourSupport System Options MaintenanceSupport Overview System OverviewPlain Config Reset to Factory Default SettingsScripting File UploadTroubleshooting TroubleshootingEmergency Recovery Procedure Checking the FirmwareProduct cannot be accessed from a browser Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Basic Product is accessible locally but not externallyProblems with streaming H.264 Video and image problems, general Status and Network indicator LEDs are flashing red rapidlyVideo Camera Settings Key framesTechnical Specifications Technical SpecificationsMaintenance Installation aids Function/group Specifications System ApplicationMemory Power ConnectorsPerformance Considerations Function/group Specifications IncludedAccessories License Video M2.2