Axis Communications M3114-R Key frames, Video and image problems, general, Video Camera Settings

Page 45

AXIS M3114-R Network Camera

Troubleshooting

Lower frame rate than

See Performance Considerations, on page 48.

expected

Reduce the number of applications running on the client computer.

 

 

Limit the number of simultaneous viewers.

 

Check with the network administrator that there is enough bandwidth available.

 

Check in the AMC Control Panel (H.264 tag) that video processing is NOT set to Decode only

 

key frames.

 

Lower the image resolution.

 

The maximum frames per second is dependent on the utility frequency (60/50 Hz) of the Axis

 

product. See Technical Specifications, on page 46.

Status and Network indicator LEDs are flashing red rapidly

 

 

Hardware failure

Contact your Axis reseller.

Video and image problems, general

 

 

Image unsatisfactory

Check the video stream and camera settings under Setup > Video > Video Stream and Setup >

 

Video > Camera Settings.

Motion Detection triggers unexpectedly

 

 

Changes in luminance

Motion detection is based on changes in luminance in the image. This means that if there are

 

sudden changes in the lighting, motion detection may trigger mistakenly. Lower the sensitivity

 

setting to avoid problems with luminance.

45

Image 45
Contents Axis M3114-R Network Camera Liability About this documentIntellectual Property Rights Equipment ModificationsAxis M3114-R Network Camera Table of ContentsConnectors Hardware OverviewHardware Overview Color Indication LED IndicatorsAccessing the Product Accessing the ProductAccess from a Browser Set the Root Password Accessing the Product Access from the InternetNetwork TCP/IP Advanced Click Create self-signed certificateSet Power Line Frequency Live ViewControls on the Live View PTZ Controls Axis Media Control viewer toolbarAxis M3114-R Network Camera Media Streams How to Stream H.264Media Streams Axis Media Control AMCAlternative Methods of Accessing the Video Stream Axis M3114-R Network Camera Setting Up the Product Setting Up the ProductBasic Setup Video VideoVideo Stream Pixel CounterStream Profiles Image264 Exposure Settings Camera SettingsImage Appearance White BalanceOverlay Video View AreaOverlay Image Go to Video Video Stream and select the Image tabGo to Video Overlay Image Privacy MaskLive View Config Live View ConfigDefault Viewer for Browsers Viewer Settings User Defined LinksBrowser Viewer Description PTZ Pan Tilt Zoom Preset PositionsPTZ Pan Tilt Zoom Guard TourControls AdvancedDetectors DetectorsCamera Tampering Motion DetectionMotion Detection Parameters Set Up Motion Detection WindowsDefault values Low level 0%Recommended values Applications ApplicationsEvents EventsConvert Event Types to Action Rules Setting Up an Action RuleRecipients Go to Events Action Rules and click AddRecurrences SchedulesAxis M3114-R Network Camera Recordings RecordingsRecording List Continuous RecordingSystem Options System OptionsSecurity UsersDate & Time IeeeCertificates Network Basic TCP/IP SettingsAdvanced TCP/IP Settings NAT traversal port mapping for IPv4 HttpSmtp email QoS Quality of ServiceUPnPTM StorageRTP/H.264 BonjourSupport System Options MaintenanceSupport Overview System OverviewPlain Config Reset to Factory Default SettingsScripting File UploadTroubleshooting TroubleshootingEmergency Recovery Procedure Checking the FirmwareSymptoms, Possible Causes and Remedial Actions Problems setting the IP addressProduct cannot be accessed from a browser Product is accessible locally but not externally Problems with streaming H.264Basic Video and image problems, general Status and Network indicator LEDs are flashing red rapidlyVideo Camera Settings Key framesTechnical Specifications Technical SpecificationsMaintenance Installation aids Function/group Specifications System ApplicationMemory Power ConnectorsFunction/group Specifications Included Accessories License VideoPerformance Considerations M2.2