AXIS M10 Series | Page 5 |
Unit connectors
Network connector -
Power connector - Mini DC connector
I/O terminal connector (AXIS M1054 only)
The
The terminal connector is used in applications for motion detection, event triggering, alarm notification via email, and image storage to FTP locations.
•Input - for connecting a push button, for example. If the push button is pressed, the state changes and the input becomes active (shown under Events > Port Status).
•Output - connects an alarm device that can be activated by Output buttons on the Live View page, or by an Event Type. The output shows as active (Events > Port Status) if the alarm device is activated.
Function | Pin | Notes |
|
|
| |
|
|
|
|
|
|
|
GND | 1 | Ground |
|
|
| |
|
|
|
| |||
3.3V DC | 2 | Can be used to power auxiliary equipment. | ||||
Power |
| Note: This pin can only be used as power out. | ||||
|
|
|
| |||
Digital Input | 3 | Connect to GND to activate, or leave floating (or | ||||
|
| unconnected) to deactivate. | ||||
|
|
|
|
|
|
|
Transistor | 4 |
|
|
|
| Uses an |
Output |
|
|
|
|
| with the source connected to GND. If |
|
|
|
|
|
| used with an external relay, a |
|
|
|
|
|
| diode must be connected in parallel |
|
|
|
|
|
| |
|
| Pin 4 |
|
|
| with the load, for protection against |
|
|
| Pin 2 |
| voltage transients. | |
|
|
| Pin 3 |
| Pin 1 | |
|
|
|
|
| ||
|
|
|
|
|
|
|