Logs & Reports - when contacting Axis support, please be sure to provide a valid Server Report with your query.

View Information - The Log file, the Server Report and the Parameter List all provide valuable information for troubleshooting and when contacting Axis support.

Configuration

Log Level for Log Files - from the drop-down list, select the level of information to be added to the Log file

Log Level for Email - from the drop-down list, select the level of information to send as email and enter the destination email address.Advanced

Scripting is an advanced function that provides the means for customizing and using scripts.

Caution!

The scripting function is a very powerful tool. Improper use may cause unexpected behavior or even loss of contact with the unit. If a script does cause problems, reset the unit to its factory default settings (in which case, a previously saved backup file will be useful for returning the unit to its latest configuration).

Axis strongly recommends that you do not use this function unless you fully understand its consequences. Axis support provides no assistance for customized scripts.

For more information, please visit the Developer pages at www.axis.com/developer

Plain Config - this function is for the advanced user with previous experience of configuring Axis cameras. All parameters can be set and modified from this page. Help is available via the links on the standard setup pages.

About

Third Party Software Licenses - Click View licenses for a list of the licensed software used in the AXIS 209FD/FD-R Network Camera.

Resetting to the factory default settings

To reset the camera to the original factory default settings, go to the System Options > Maintenance web page (as described in Maintenance, on page 29) or use the Control button, which is found inside the camera cover (see Overview, on page 6) as described below:

Using the Control Button

To reset the camera to the factory default settings using the Control Button:

1.Remove the camera’s cover.

2.Disconnect the network to remove power.

3.Press and hold the Control button while reconnecting the cable.

4.Keep the Control button pressed until the Status Indicator color changes to amber (this may take up to 15 seconds).

5.Release the Control button.

6.When the Status Indicator changes to Green (which may take up to 1 minute), the process is complete and the camera has been reset. The unit will now have the default IP address 192.168.0.90

Unit connectors

(AXIS 216FD) network connector - Female RJ-45 Ethernet connector for 10BaseT/100BaseTX. Supports Power over Ethernet. Using shielded cables is recommended.

Image 30
Contents User’s Manual About this Document CanadaContents Glossary of Terms Index Key features Product overviewDescription Overview LED Indicators LEDAccessing the Camera Access from a browserAxis Media Control Setting the root password Accessing the camera from the InternetLive View How to stream MPEG-4 Video StreamsMotion Jpeg Alternative methods of accessing the video streamMPEG-4 clients Axis Media Control AMCConfiguration Accessing the Setup toolsImage Appearance Video & Image SettingsText Overlay Settings Video StreamOverlay/Mask Overlay/Mask TypeUpload and use an overlay/mask Overlay image requirementsImage Formats Image Size Advanced Camera Settings Lighting ConditionsLow Light Behavior Advanced MPEG-4 Settings GOV SettingsBit Rate Control Layout Live View ConfigDefault Video Format Action ButtonsDefault Viewer Viewer SettingsEvent Types Event ConfigurationEvent Servers DefinitionsClick Add triggered on the Event types How to set up a triggered eventTriggered Events Pre-trigger and Post-trigger buffersScheduled Events Camera Tampering Axis 209 FD-R/FD-R M12Motion Detection Object SizeIP Address Filtering System OptionsSecurity ReferralsServices Network Basic TCP/IP SettingsIP Address Configuration Date & TimeNetwork Advanced TCP/IP Settings Network Traffic WAN internetQoS Quality of service QoS SettingsSmtp email UPnP LED SettingsMaintenance BonjourConfiguration Resetting to the factory default settingsUnit connectors Using the Control ButtonAxis 209FD/FD-R/FD-R M12 Checking the firmware TroubleshootingEmergency recovery procedure Upgrading the firmwareAxis Support Camera is inaccessible Symptoms, Possible Causes and Remedial ActionsCamera is accessible locally, but not externally BrowserPoor quality snapshot images Browser freezesMotion Detection triggers unexpectedly Technical Specifications Specification ModelsSpecification Installation General performance considerations Optimizing your systemBandwidth Axis 209FD/FD-R/FD-R M12 Glossary of Terms Etrax Ethernet Token Ring Axis Axis own microprocessorSee also IP Internet Protocol Megapixel See Pixel VOP See VOPSSL/TSL Secure Socket Layer/Transport Layer Security URL Uniform Resource Locator An address on the networkAxis 209FD/FD-R/FD-R M12 Index AMC