[Command alarm]

[Originating port number]

Select "ON" or "OFF" to determine whether or not to

Select a port number to be used to receive the com-

receive the command alarm.

mand alarm.

The command alarm is the function that provides notifi-

Available port number: 1 - 65535

cation of a Panasonic protocol alarm from the other

Default: 8181

cameras. When "ON" is selected, alarm actions will be

 

performed between multiple cameras.

 

Default: OFF

 

Configure the settings relating to the camera action at an alarm occurrence

Click the [Alarm] tab on the "Alarm setup" page. (pages 4 and 5: How to display/operate the setup menu)

Camera motion on alarm

The settings relating to the camera action at an alarm occurrence can be configured in this section. Refer to pages 38, 41 and 42 for further information about the settings relating to the alarm, the alarm image and the alarm output terminal.

[Terminal alarm 1]

Select an action to be taken when a terminal alarm 1 is detected from the following.

OFF: Does not take any action even when a terminal alarm 1 is detected.

1-256:When the registered preset position is selected, the camera will move to the selected preset position when a terminal alarm 1 is detected.

Auto track: When a terminal alarm 1 is detected, the camera will start the auto tracking.

When the home position is set, the camera will start auto tracking after moving to the home position once.

Patrol 1: When a terminal alarm 1 is detected, the cam- era will start the patrol 1 operation.*

Default: OFF

[Terminal alarm 2]

Select an action to be taken when a terminal alarm 2 is detected from the following.

OFF: Does not take any action even when a terminal alarm 2 is detected.

1-64:When the registered preset position is selected, the camera will move to the selected preset position when a terminal alarm 2 is detected.

Auto track: When a terminal alarm 2 is detected, the camera will start the auto tracking.

When the home position is set, the camera will start auto tracking after moving to the home position once.

Patrol 2: When a terminal alarm 2 is detected, the cam- era will start the patrol 2 action.*

Default: OFF

[Terminal alarm 3]

Select an action to be taken when a terminal alarm 3 is detected from the following.

OFF: Does not take any action even when a terminal alarm 3 is detected.

1-256:When the registered preset position is selected, the camera will move to the selected preset position when a terminal alarm 3 is detected.

Auto track: When a terminal alarm 3 is detected, the camera will start the auto tracking.

When the home position is set, the camera will start auto tracking after moving to the home position once.

39

Image 39
Contents WV-NW964 Contents About these operating instructions Trademarks and registered trademarksViewer software Step How to display the setup menuHow to operate the setup menu About the setup menu window 3Setup Network setup buttonSchedule setup button Maintenance buttonConfigure the basic settings Basic Configure the basic settings of the camera Basic setupDefault on Alarm status update modeDefault Real time Alarm status portConfigure the settings relating to the NTP server NTP SD memory card setup SD memory card information Page Step Image capture size Qvga Image capture size VGAManual Configure the settings relating to the logs LOGAlarm FTP errorOFF SD memory Save trigger Overwrite Save logs Card LOG tab SD memory card tab Logs and associated imagesSave logs Card SD memoryRefresh interval Jpeg Jpeg setupDefault VGA Image quality Default 5 fpsMPEG-4 setup Available value 1 Default Default Unicast port2 AudioDefault Multicast address Default Multicast TTLHome position Default OFF Camera title on screen 0-9, A-ZDefault 1 min Image Hold Camera title on screenStabilizer Pan·Tilt degree/Zoom ratio displayTilt Angle Patrol Image AdjustPreset Position Auto PanAbout SUPER-D 3 Super Dynamic function Super DynamicDefault High Wait time Default AutoDefault on High Sensitivity up Black & white modeBlue Gain Default ATW1Default High Chroma gain level Red GainSet mask areas Edit the settings of the registered preset position Register the preset positionPosition No Auto pan PositionGO button Number of patrol patternLearn patrol pattern Zone select Zone settingPrivacy zone ModeAudio bit rate Configure the settings relating to audio AudioAudio mode Default 32 kbpsAudio output volume PC to Camera Mic input volume Camera to PCDefault Middle Mic input interval Camera to PC Default 40 msecConfigures the multi-screen settings Multi-screen setup IP addressNumber of characters for the IP address 1 Configure the alarm settings Alarm setup Configure the settings relating to the alarm AlarmAlarm setup Camera motion on alarm Command alarm Originating port numberAvailable port number 1 Configure the settings relating to the alarm image Alarm image setupDefault OFF Command alarm Default 1 fps Number of images To FTP setupAlarm image FTP transmission Post alarm Transmission intervalConfigure the settings relating to the alarm out terminal Alarm output terminal setupAUX name Set the VMD areas VMD area Status Default OFF Detection sensitivitySet the VMD areas for each preset position Default Middle Delete the VMD area set for the designated preset positionMail notification setup Configure the settings relating to Panasonic alarm protocol Panasonic alarm protocol setupPanasonic alarm protocol Number of characters for the password 4 32 char User authenticationDefault OFF User name Password Retype passwordDefault OFF Access level Host authenticationConfigure the settings relating to the mail server Mail Configure the settings of the servers Server setupConfigure the settings relating to the FTP server FTP Configuring the network settings Network setup Configure the network settings NetworkNetwork setup Default Manual Primary DNS, Secondary DNS Default gatewayUnavailable IP addresses for the default gate- way Available port number 1 Default Port numbers already in useWAN Number of characters for the host name 1 64 char Configure the settings relating to Ddns DdnsAccess interval Default OFF Host nameConfigure the settings relating to Snmp Snmp Number of characters for the directory name 1 Default OFF DirectoryFTP periodic transmission FTP periodic transmissionSchedule setup How to configure the schedule settingsInterval How to delete the set schedule How to set the schedules Time & date Maintenance of the camera MaintenanceError message Check the system log System logHow to upgrade the firmware Upgrade the firmware UpgradeRestart Initialize setup data and Html dataInitialize/restart the camera Initialization Initialize Html dataSetup screen Step Displaying the Help screenHelp screen Step Error indications relating to Smtp Error indications relating to FTPCategory Indication Description Error indications relating to Ddns Error indications relating to NTPError indications relating to login Troubleshooting Symptom Installation Guide Cause/solution Reference Pages Installation Guide Operation Instructions Symptom Solutions Reference Pages Directory structure of drive B Group WAN IP address Protocol LAN IP address LAN port Group LAN IP address LAN port WAN IP address ProtocolN0907-0 3TR005323AAB
Related manuals
Manual 21 pages 50.64 Kb

WV-NW964, WV-NS954 specifications

The Panasonic WV-NW964 and WV-NS954 are advanced network cameras designed for high-performance surveillance in various applications. Both models offer a remarkable combination of features, technologies, and characteristics that make them ideal for security monitoring in both indoor and outdoor environments.

The WV-NW964 is a high-definition network camera equipped with a 1/3-inch progressive scan CCD sensor, delivering exceptional image quality with resolutions up to 1280x960 pixels. It is particularly well-suited for situations where clarity and detail are paramount, such as in retail spaces or critical infrastructure facilities. The camera supports H.264 compression technology, which allows for efficient video streaming while maintaining high image quality. This feature is particularly useful for reducing bandwidth requirements and storage costs without compromising surveillance effectiveness.

On the other hand, the WV-NS954 is a PTZ (pan-tilt-zoom) network camera that provides extensive flexibility in monitoring wide areas. With its 3x optical zoom lens, it enables users to focus on specific subjects or areas of interest without loss of detail. The camera's ability to pan 360 degrees and tilt up to 90 degrees allows for comprehensive coverage of large spaces, making it ideal for applications such as parking lots, open-air venues, and warehouses.

Both cameras are equipped with advanced features such as digital noise reduction and wide dynamic range (WDR) technology, ensuring clear images in varying lighting conditions. The WDR feature is particularly beneficial in scenarios where backlighting can obscure details, allowing for better visibility of individuals or objects even in challenging environments. Additionally, the cameras support multiple streaming formats and resolutions, providing flexibility in how video feeds are accessed and managed across different network systems.

With built-in motion detection and event-triggered recording capabilities, both cameras enhance security by providing alerts when unusual activity is detected. Users can customize alert settings based on specific needs, ensuring efficient and timely response to potential security threats. Furthermore, both models are designed with robust IP66-rated weatherproofing, making them suitable for outdoor deployment in various weather conditions without the risk of damage.

In summary, the Panasonic WV-NW964 and WV-NS954 network cameras deliver outstanding performance through their advanced imaging technologies and versatile functionalities. With features tailored for high-quality surveillance, efficient data management, and user-friendly operation, they are essential tools for enhancing security in a variety of applications.