Panasonic WV-CL920A operating instructions Electronic Sensitivity Enhancement Sens UP

Page 26

5.Electronic Sensitivity Enhancement (SENS UP)

There are two modes for SENS UP.

AUTO: If you select x32 AUTO, for example, the sensitivity is raised automatically to x32 max. When AUTO is selected, AGC is automatically set to ON.

FIX: If you select x64 FIX, for example, the sensitiv- ity is raised to just x64.

** CAM SET UP **

CAMERA ID

OFF

ALC/ELC

 

ALC

SHUTTER

 

OFF

 

AGC

 

ON (DNR-H)

SENS UP

 

OFF

 

SYNC

 

INT

 

WHITE BAL

ATW1

MOTION DET

OFF

 

LENS DRIVE

DC

 

END

SET UP ENABLE

Notes:

While the SENS UP function is selected, noise, spots or a whitish phenomenon may appear in the picture when the sensitivity of the camera is increased. This is a normal phenomenon.

x64FIX does not appear for the SENS UP parame- ter on the system controller setup menu.

In case of using the WV-CU204 or WV-CU254 Controller, status does not appear correctly for the SENS UP parameter on the setup menu.

Move the cursor to the SENS UP parameter and select the parameter for electronic sensitivity enhancement. The preset values for SENS UP (electronic sensitivity

enhancement) change by pressing or as fol- lows:

OFF X2 AUTO X4 AUTO X6 AUTO X10 AUTO X16 AUTOX32 AUTO

X64 FIX X32 FIX X16 FIX X10 FIX X6 FIX X4 FIX X2 FIX OFF

-27-

Image 26
Contents Operating Instructions Bol, within an equilateral triangle, is Contents Features PrefaceDo not attempt to disassemble the camera PrecautionsClean the CCD faceplate with care Handle the camera with careMajor Operating Controls and Their Functions WV-CL9240Gen-lock Termination Switch Hi-Z, G/L 75Ω Auto Iris Lens ConnectorFlange-back Adjusting Ring FB 1Gen-lock Input Connector GEN-LOCK3Power Cord Socket 4AC/DC Compatible Input Terminal DC 12V IN/AC 24VWV-CL924 12 V DC/24 V AC ConnectionsWV-CL920 120 V AC 60Hz AC Power Supply Recommended wire gauge sizes for 24 V AC lineInstallation of Auto Iris Lens Connector Mounting the Lens Focus or FLANGE-BACK Adjustment Installation of Camera Mounting from the topSetup Camera Setup MenuATW1 ATW2 AWC Opening the Setup Menu Press and hold down for 2 seconds or moreSetup Operation All Reset OperationEditing the CAM SET UP Menu Important NoticeTo edit the Camera ID Setting ProceduresCamera Identification Camera ID Setting To enter a blank space in the Camera IDTo determine the display position of the Camera ID Light Control Setting ALC/ELCTo erase all characters in the editing area ALC Mode with Preset on Back Light Compensation Back Light Comp ALC Mode with Preset OFF Blinking Shutter Speed Setting Shutter Gain Control Setting AGC ON/OFFElectronic Sensitivity Enhancement Sens UP Synchronization Setting Sync Important NoticesVBS Gen-lock Mode Extvbs Page VS Gen-lock Mode Extvs Line-lock Sync Mode LLPhase Coarse ATW1 Auto Tracing White Balance White Balance Setting White BALAuto-Tracing White Balance Mode ATW Manual Fine Adjustment for AWC ATW Select AWC →Motion Detector Setting Motion DET Lens Drive Signal Selection Lens DriveSpecial Menu Special Burst BW To reset to the factory settings Prevention of Blooming and SmearSpecifications AGCPage Standard Accessories Optional Accessories Panasonic Canada Inc