Panasonic WV-CL920A AC Power Supply, Recommended wire gauge sizes for 24 V AC line

Page 10

2.24 V AC Power Supply

Connect the power cable to the AC/DC compatible input terminal on the rear panel of the camera.

DC 12V

AC 24V

IN

IN

 

1

 

2

GND

24 V AC, 60 Hz

 

(19.5 V - 28 V)

 

 

Recommended wire gauge sizes for 24 V AC line.

Copper wire

 

#24

#22

#20

#18

size (AWG)

 

(0.22 mm2)

(0.33 mm2)

(0.52 mm2)

(0.83 mm2)

 

 

 

 

 

 

 

Length

 

(m)

95

150

255

425

of Cable

 

 

 

 

 

 

 

 

 

 

 

 

(Approx.)

 

(ft)

314

495

842

1 403

 

 

 

 

 

 

 

Caution:

To prevent fire or electric shock hazard,use a UL listed cable (VW-1, style 1007).

Video Cable

1.It is recommended to use a monitor whose resolu- tion is at least equal to that of the camera.

2.The maximum extensible coaxial cable length between the camera and the monitor is shown below.

Type of

 

RG-59/U

RG-6/U

RG-11/U

RG-15/U

coaxial cable

 

(3C-2V)

(5C-2V)

(7C-2V)

(10C-2V)

 

 

 

 

 

 

Recommended

(m)

250

500

600

800

maximum

 

 

 

 

 

 

 

 

 

 

cable length

(ft)

825

1 650

1 980

2 640

 

 

 

 

 

 

-10-

Image 10
Contents Operating Instructions Bol, within an equilateral triangle, is Contents Features PrefaceDo not attempt to disassemble the camera PrecautionsClean the CCD faceplate with care Handle the camera with careMajor Operating Controls and Their Functions WV-CL9240Gen-lock Termination Switch Hi-Z, G/L 75Ω Auto Iris Lens ConnectorFlange-back Adjusting Ring FB 1Gen-lock Input Connector GEN-LOCK3Power Cord Socket 4AC/DC Compatible Input Terminal DC 12V IN/AC 24VWV-CL920 120 V AC 60Hz ConnectionsWV-CL924 12 V DC/24 V AC AC Power Supply Recommended wire gauge sizes for 24 V AC lineInstallation of Auto Iris Lens Connector Mounting the Lens Focus or FLANGE-BACK Adjustment Installation of Camera Mounting from the topSetup Camera Setup MenuATW1 ATW2 AWC Opening the Setup Menu Press and hold down for 2 seconds or moreSetup Operation All Reset OperationEditing the CAM SET UP Menu Important NoticeTo edit the Camera ID Setting ProceduresCamera Identification Camera ID Setting To enter a blank space in the Camera IDTo erase all characters in the editing area Light Control Setting ALC/ELCTo determine the display position of the Camera ID ALC Mode with Preset on Back Light Compensation Back Light CompALC Mode with Preset OFF Blinking Shutter Speed Setting Shutter Gain Control Setting AGC ON/OFFElectronic Sensitivity Enhancement Sens UP Synchronization Setting Sync Important NoticesVBS Gen-lock Mode Extvbs Page VS Gen-lock Mode Extvs Line-lock Sync Mode LLPhase Coarse Auto-Tracing White Balance Mode ATW White Balance Setting White BALATW1 Auto Tracing White Balance Manual Fine Adjustment for AWC ATW Select AWC →Motion Detector Setting Motion DET Lens Drive Signal Selection Lens DriveSpecial Menu Special Burst BW To reset to the factory settings Prevention of Blooming and SmearSpecifications AGCPage Standard Accessories Optional Accessories Panasonic Canada Inc