36 | The System Options | AXIS 230 |
Ports & Devices
IO Ports
This page allows configuration of the two inputs and one output supported by the AXIS 230. Ports can be given descriptive names, and their Normal state can be configured.
The normal state describes the inactive state for the port. It is also an indication of the function of the connected equipment and how it is activated. For example, if the activation circuit in a door switch connected to an input is normally closed, this means that as long as the door is closed then the state is also closed (inactive). When the door is opened the door sensor will be active and the input will no longer be in its normal state. This is how events based on external equipment are triggered.
Thus, in the I/O port list, if the Normal state for an input is set as Open, but the Current state is shown as Closed, then the port has been activated, and vice versa.
Important!
Please note that some external devices may behave incorrectly in the event of an error condition, e.g. a power cut.
COM Ports RS-232/RS-485
The COM1 port on the AXIS 230 is accessed via the terminal block
Devices (Pan/Tilt devices, etc.) connected to the
Select the port to configure and then choose the Usage for the port, whereupon the relevant settings will be displayed. To make
For detailed listings of all of the available settings for each mode, the supported Pan/Tilt devices, as well as more information about the different interface modes and pinout info, please the online help, available from the setup pages. See also Unit Connections, on page 49.