7. System Testing

1.Follow each instruction below.

2.Verify that the system operates as indicated under each instruction. Refer to the system owners manual.

3.Check the appropriate wire connection(s) and/or fuse(s) if the unit fails to perform a specific function. Also check that any options pertaining to the function are programmed properly.

Security Operation

Press LOCK once:

1.Doors lock.

2.Courtesy lights (if on) shut off.

3.Unit checks to see if doors, hood or trunk are open. If open, siren (or horn) sounds once, parking lights flash once, and system enters pre-arm mode.

Pre-arm mode:

1.The unit will wait for the open door, hood or trunk to be closed. The LED is solid during pre-arm.

2.If the entrance is secured, the siren/horn will sound again, parking lights will flash once, and the system will arm.

3.If the entrance is not secured after 4 minutes, the siren/horn will sound again, parking lights will flash once, the system will arm, and the defective trigger or entrance will be ignored.

Note: If entrance is secured after 4 minutes, the system will immediately begin to monitor the entrance for intrusion.

If the above conditions are not present:

1.Vehicle starter is disabled.

2.Siren (or horn) sounds twice / parking lights flash twice.

3.The LED flashes slowly for duration of arm cycle.

4.After 5 seconds, unit monitors all entrances and sensors.

If door, sensor, hood/trunk or ignition input is triggered:

1.Siren/horn sounds for 30 seconds or until UNLOCK is pressed.

2.Parking lights flash

3.If the system is triggered, pressing DISARM (once) will end the 30-second cycle.

The LED flashes a number of times to indicate which input triggered the alarm:

Number of flashes:

1 - Interior Theft Sensor (Shock Sensor)

2 - Hood/Trunk input

3 - Door Input

Image 22
Contents CA 160 Installation Instructions For Authorized Dealers 800CA-160 System Layout CA- 160 System Layout Pin Power Harness Manual Feature Programming RF ProgrammerSelecting Programmable Features Using the M1 functionCA 160 Programming Guide RF Programmer Receive 4 Chirps Setup & ProgrammingTransmitter Programming 3 Chirps Shock Sensor Programming 5 ChirpsBattery Power RED PIN Main Power HarnessVolts Ignition Input/Output Pink Negative Door Input Green Basic Installation 22 PIN Base HarnessDome Light Supervision Output +/- BLACK/WHITE Positive Door Input PurpleHeadlight Output LT. GREEN/ORANGE Ground When Armed Output OrangePIN Base Harness Hood Pin Input GraySiren Output + Brown Instant Trigger Input BLUE/WHITEParking Light Output +/- White Trunk Pin Switch Input Blue Unlock Switch Sense LT. BLUE/GREENSong Bird Output BROWN/WHITE SB1 Accessory required Manual ARM input LT. BLUE/REDChannel 3 PINK/GREEN PIN Advance Channel HarnessChannel 2 PINK/BLACK Channel 4 PINK/BLUEDiagram Door LocksFused +12 Volt Battery Source Door Lock Switch Diagram Fused +12 Volt Battery Source Green Lock Output Door Lock Switch Adding Aftermarket Actuators Accessory Connectors System POWER-UP ProcedureIf the above conditions are not present Pre-arm modeSecurity Operation Press Lock once If door, sensor, hood/trunk or ignition input is triggeredPress Find Press DisarmPress Disarm twice Press and hold Panic for 2 seconds