Soundstream Technologies CA 160 installation instructions Fused +12 Volt Battery Source

Page 18

4. DOOR LOCKS

Negative Lock Output / Positive Unlock Output (GREEN)

Negative Unlock Output / Positive Lock Output (BLUE)

Negative Second Door Unlock Output (BLUE/GREEN)

One Wire Negative Multiplexed and One Wire Negative Multiplexed with 2-step Unlock Feature:

All Door Lock and Unlock: Locate the lock / unlock wire at the vehicle’s lock / unlock switch.

Verification: This wire will show variable ground when the switch is activated. Please consult the wire and location chart for specific resistor values for your vehicle.

Driver’s Door Unlock: Locate the unlock motor wire directly from the actuator inside the driver’s door.

Verification: This wire will rest at ground and register positive voltage when the driver’s door is unlocked.

Connect the GREEN and BLUE or BLUE/GREEN wires shown in diagram 12 below. Use (1) Code Alarm part DLRK (Door Lock Relay Kit, not included) or (2) Code Alarm part HDRLY (SPDT relay, not included).

Note: When adding the 2 step unlock feature the BLUE/GREEN 2nd door unlock wire will be used to unlock all vehicle doors on the second press of unlock. An additional SPDT relay not supplied (Code Alarm part HDRLY) is required. Connect the relay as shown in diagram 13 to unlock the driver’s door on the first press of unlock

Diagram 12

GREEN (-) Lock Output

87

Door

Lock Switch

87a

86

30

 

BLUE (-) Unlock Output

Chassis Ground

Or BLUE/GREEN 2nd

Door Unlock Output When

 

87Installing The 2-Step Unlock Feature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

87a

 

 

 

 

Fused +12 Volt

 

 

 

 

 

 

85

Battery Source

86

 

 

 

 

 

85

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lock

Resistor

Resistor

 

 

Vehicle Door Lock

 

 

Control Relays

Unlock

 

 

 

 

Diagram 13

Fused +12 Volt

 

 

Battery Source

87

 

 

 

 

87a

BLUE (-) Unlock Output

 

86

85

 

30

 

From Keyless Entry

 

To Unlock Side Of

Module Or Door

X

Driver's Door Actuator

Lock/Unlock Relays

CUT

 

 

 

Image 18
Contents CA 160 Installation Instructions For Authorized Dealers 800CA-160 System Layout CA- 160 System Layout Pin Power Harness Manual Feature Programming RF ProgrammerSelecting Programmable Features Using the M1 functionCA 160 Programming Guide RF Programmer Receive 4 Chirps Setup & ProgrammingTransmitter Programming 3 Chirps Shock Sensor Programming 5 ChirpsPIN Main Power Harness Battery Power REDVolts Ignition Input/Output Pink Negative Door Input Green Basic Installation 22 PIN Base HarnessDome Light Supervision Output +/- BLACK/WHITE Positive Door Input PurpleHeadlight Output LT. GREEN/ORANGE Ground When Armed Output OrangePIN Base Harness Hood Pin Input GrayInstant Trigger Input BLUE/WHITE Siren Output + BrownParking Light Output +/- White Trunk Pin Switch Input Blue Unlock Switch Sense LT. BLUE/GREENSong Bird Output BROWN/WHITE SB1 Accessory required Manual ARM input LT. BLUE/REDChannel 3 PINK/GREEN PIN Advance Channel HarnessChannel 2 PINK/BLACK Channel 4 PINK/BLUEDiagram Door LocksFused +12 Volt Battery Source Door Lock Switch Diagram Fused +12 Volt Battery Source Green Lock Output Door Lock Switch Adding Aftermarket Actuators Accessory Connectors System POWER-UP ProcedureIf the above conditions are not present Pre-arm modeSecurity Operation Press Lock once If door, sensor, hood/trunk or ignition input is triggeredPress Find Press DisarmPress Disarm twice Press and hold Panic for 2 seconds