Soundstream Technologies CA 160 installation instructions Adding Aftermarket Actuators

Page 20

4. DOOR LOCKS

Negative Lock Output / Positive Unlock Output (GREEN)

Negative Unlock Output / Positive Lock Output (BLUE)

Negative Second Door Unlock Output (BLUE/GREEN)

Adding Aftermarket Actuators:

After installing aftermarket actuators, Code Alarm part DA-1 (not supplied). Connect the GREEN and BLUE wires shown in diagram 16 below. Use (1) Code Alarm part DLRK (Door Lock Relay Kit, not included) or

(2) Code Alarm part HDRLY (SPDT relay, not included).

Diagram 16

 

 

 

 

 

 

Fused +12 Volt

 

87

 

Battery Source

 

 

 

Door Lock

87a

 

GREEN (-) Lock Output

Actuator

85

86

 

 

 

 

30

 

Chassis

 

 

 

M

 

 

Ground

 

 

 

 

 

 

Fused +12 Volt

 

87

 

Battery Source

 

 

 

 

87a

 

BLUE (-) Unlock Output

 

86

85

 

 

 

30

 

 

 

 

 

Chassis

 

 

 

Ground

Image 20
Contents CA 160 Installation Instructions For Authorized Dealers 800CA-160 System Layout CA- 160 System Layout Pin Power Harness Manual Feature Programming RF ProgrammerSelecting Programmable Features Using the M1 functionCA 160 Programming Guide Setup & Programming Transmitter Programming 3 ChirpsRF Programmer Receive 4 Chirps Shock Sensor Programming 5 ChirpsVolts Ignition Input/Output Pink PIN Main Power HarnessBattery Power RED Basic Installation 22 PIN Base Harness Dome Light Supervision Output +/- BLACK/WHITENegative Door Input Green Positive Door Input PurpleGround When Armed Output Orange PIN Base HarnessHeadlight Output LT. GREEN/ORANGE Hood Pin Input GrayParking Light Output +/- White Instant Trigger Input BLUE/WHITESiren Output + Brown Unlock Switch Sense LT. BLUE/GREEN Song Bird Output BROWN/WHITE SB1 Accessory requiredTrunk Pin Switch Input Blue Manual ARM input LT. BLUE/REDPIN Advance Channel Harness Channel 2 PINK/BLACKChannel 3 PINK/GREEN Channel 4 PINK/BLUEDiagram Door LocksFused +12 Volt Battery Source Door Lock Switch Diagram Fused +12 Volt Battery Source Green Lock Output Door Lock Switch Adding Aftermarket Actuators Accessory Connectors System POWER-UP ProcedurePre-arm mode Security Operation Press Lock onceIf the above conditions are not present If door, sensor, hood/trunk or ignition input is triggeredPress Disarm Press Disarm twicePress Find Press and hold Panic for 2 seconds