The VFO Knob is of variable torque type. When the lever at the left of the knob is set to NORM, the knob can be rotated quickly because of the flywheel effect. When the lever is set to TIGHT, the knob is given a heavy torque and hence the knob will not rotate accidentally by external shock. This feature is useful for fine tuning or mobile opera- tion.
5-10 OPERATION OF 2 VFOs
The
By using the FUNCTION switch, the desired VFO can be
selected. The use of two VFO’s also permits Operation with
their own frequencies (Cross | channel | Operation) | such as | ||||
table | below | Shows the | positions | ||||
of the FUNCTION switch | and | VFO’s | selected. |
|
| ||
The two VFO’s (A and | BI | can | be | operated | in | different | |
bands (for example, VFO | A: | 144 | MHz, VFO B: | 430 MHz; |
or in the same band. They can also be used as a memory. Examples:
1 . With your contact’s schedule frequency | stored | in VFO |
B, you can operate VFO A until your | contact | Starts |
transmitting. |
|
|
2.During FM Operation, you can locate a
FUNCTION | R E C E P T I O N | TRANSMISSION | |
SWITCH | |||
|
|
When the MODE switch is changed to or from
Position, the operating frequency becomes as shown table
3.
|
|
|
|
|
|
Frequency | 145.317.7 | 145.317.6 | 145.315.0 | 145.315 | |
displayed |
|
|
|
|
|
| 145.312.5 | 145.315 | 145.315.0 | ||
| (NOTE: "1) | (NOTE: | '2) |
|
|
|
| Table | 3 |
|
|
Note 1:
*1 When the F. STEP switch is turned OFF, the frequency will shift to the nearest 12.5 kHz step frequency
within the displayed frequency.
*2 When the F. STEP switch is turned ON, the frequency will shift the nearest 5 kHz step frequency within the displayed frequency.
The 100 Hz digit disappears.
Note | 2: |
|
Table | 3 Shows the frequencies | of VFO A. In the |
mode, | the frequency of VFO B is shifted in the same way. | |
In the | SSB mode, the frequency | bellow 10 kHz Order may |
be changed.
Table 2
5-11 USE OF FM-CH
With the MODE switch set to
Operation changes to click type. In the OFF Position of the
F . STEP switch, the channel frequency shifts up in
12.5 kHz Steps, and | in the ON Position, in 5 kHz Steps. |
4 3 3 . 0 0 0 | 4 3 3 . 0 0 5 |
4 3 3 . 0 1 2 5 | 4 3 3 . 0 1 0 |
4 3 3 . 0 2 5 0 | 4 3 3 . 0 1 5 |
4 3 3 . 0 3 7 5 | 4 3 3 . 0 2 0 |
4 3 3 . 9 8 7 5 | 433.995 |
5-12 USE OF F. STEP SWITCH
This switch is used to Change the step of VFO frequen- cy. By pressing the switch, the F. STEP LED will light. In the SSB, CW or FM mode, this switch should be set to OFF, except when the tuning knob is used. When the switch is set to ON, the frequency on the 100 Hz Order becomes even number and the frequency on the 10 kHz Order is cleared to “0”. The frequency remains the same when the switch is set to OFF.
Table 4
5-13 USE OF MEMORY
This switch is used to store the desired frequency in the memory. The frequency is stored in the channels
1 6