XTi2 Series Power Amplifiers
Integrated Processing Features
Advanced Thermal Control
In this section, you can tailor the fan speed to specific applications. You have the choice of the following modes:
t /PSNBM
t &BSMZ
t 'VMM4QFFE
The fan mode can be changed using the front panel buttons at
Advanced Monitoring
This feature allows you to have software visibility of both the Power Supply Temperature and AC Line voltage. AC Line voltage is “derived” from the amplifier rail voltage and is an approximation of the AC line voltage. This allows you to monitor the health of your amplifiers and provides for troubleshooting.
Front Panel Lock-Out
To disable or lock the buttons from the front panel, hold the Prev and Next at the same time until the screen says “locked”.
The rotary knobs (attenuators) will still operate. To unlock, hold Prev and Next until the screen says “unlocked”.
The front panel can also be locked out from the software as well from the main panel. However once it is locked in the software, it can only be unlocked from the software. You cannot unlock from the front panel. The rotary knobs (attenuators) will still operate.
page 12 | Operation Manual |