Toshiba E6580772 instruction manual Environment Specification, PG feedback specification

Page 24

E6580772

5. Specification

<Environment Specification>

Item

Specification

 

Indoor, less than 1,000 m from the sea level.

Use Environment

No direct sunlight, corrosive or explosive gas, steam, cutting dusts or dusts,

 

grinding solution, and grinding oil.

Ambient Temperature

-10 to +50

Storage Temperature

-25 to +65

Relative Humidity

20 to 90 % (No condensation)

Vibration

5.9m/s² or less

< PG feedback specification >

 

Speed control operation: [150% torque at 0 speed,

Full-vector

speed control range: 1:1000(1000 ppr PG),

operation with

speed accuracy ±0.02% (50 Hz base digital input)]

sensor

Torque control operation: [torque control accuracy ±10%,

 

(torque control range: -100 to 100%)]

PG Method

Complementary, Open-collector

PG Wiring Length

100m (Max.)(Complementary)

PG Power Supply

12V -160mA

 

120kHz or less (single-phase),

Max. Pulse Input

60kHz or less ( two-phase)

Frequency

* (In case of 2-phase open collector method, derating need to be considered)

 

Pulse duty: 50±10%

Pulse input voltage

12V dc to 15V dc

 

Manufacturer: SUMTAK Co., Ltd.

Recommended

Type: LBJ series

Encoder

Supply Voltage: 12V

 

Output Method: complementary output

 

Type of Wire: Twisted Pair Shield Cable

 

Conductor Resistance:

 

Conductor Resistance (Ω/m) x cable length (m) x 2 x power consumption (A)

Encoder Wiring

VD (V)

(Recommended

VD(V): 1.0(V) [PG for 12V]

Cable)

Applicable Wire: 0.2-1.5mm²

 

(Power Line) In case of 0.2mm² cable: maximum of 30m [Complementary PG]

 

maximum of 10m [Open collector PG]

 

KURAMO Electric: KVC-36SB , Furukawa Electric: ROVV-SB

23

Image 24
Contents Optional add-on cassette E6580772③Safety Precautions „ Transportation and Installation„ Handling in general „ Wiring „ About operation„ About disposal of Inverter < Confirmation on accessories > Introduction< Type of F10M option unit > Contents Name and function of each section AppearanceE6580772③ Name of each section terminal TLF001Z<When the unit is installed alone> <When the unit is installed with another option>Connection to the inverter Connection to the inverter„ Connection with options E6580772③ Wiring „ PG interface TB2 terminalFunctional description F10M communication functionConnection of transmission cable Setting of communication parameters Communication parameters „ F10M communication parametersE6580772 ③ „ Other parameters PG input setting E6580772③ Vector control with sensorConnection of PG ↑V aInverter Selection of encoder type 100mVector control setting parameter Basic parametersExtended Parameter Speed loop ratio gain Speed loop integration gainSetting method for status monitoring Setting method for analog monitoringMonitoring method for feedback amount Accuracy of speed controlExternal diagram Specification Environment SpecificationPG feedback specification Specifications of transmission Warranty