Toshiba E6580772 instruction manual Communication parameters, „ F10M communication parameters

Page 13

E6580772

3.1.3 Communication parameters

„F10M communication parameters

Parameter name

Title

Setting value

Details

Inverter number

f802

0 to 255

Sets inverter station address. (Note 1)

 

 

 

When using a message transmission, set the address of the

 

 

 

master station to 0 and address of the inverter station to 1 or

 

 

 

over.

Data type

f830

0, 1

Selects type of transmitting and receiving data.

selection

 

 

0: VFA7 mode

 

 

 

1:μs250 mode

Input reference

f831

0 to 16

Sets scan transmission data to be received.

setting 1

 

 

0: Without setting

Input reference

f832

 

1: Command

setting 2

 

 

2: Speed reference value

Input reference

f833

 

3: Auxiliary speed reference value

setting 3

 

 

4: Torque limit value

Input reference

f834

 

5: Positive torque limit value

setting 4

 

 

6: Negative torque limit value

Input reference

f835

 

7: Torque command value

setting 5

 

 

8: Synchronized torque bias

Input reference

f836

 

9: Tension torque bias

 

10: Load sharing gain

setting 6

 

 

 

 

11: Drooping gain

 

 

 

 

 

 

12: Speed loop proportional gain

 

 

 

13: Speed loop accumulative gain

 

 

 

14: Terminal output data

 

 

 

15: Inertia moment ratio

 

 

 

16: Expansion command

Monitor output

f841

0 to 16

Sets scan transmission data to be sent.

setting 1

 

 

0: Without setting

Monitor output

f842

 

1: Status

setting 2

 

 

2: Operation frequency

Monitor output

f843

 

3: Speed feedback value (real time)

setting 3

 

 

4: Speed feedback value (1-second filter)

Monitor output

f844

 

5: Internal torque reference value

setting 4

 

 

6: Output amperage

Monitor output

f845

 

7: Exciting amperage

setting 5

 

 

8: Torque amperage

Monitor output

f846

 

9: Overload accumulative value

 

10: Deleted torque of acceleration/deceleration torque

setting 6

 

 

 

 

11: Motor counter data

 

 

 

 

 

 

12: Error code

 

 

 

13: Input terminal data

 

 

 

14: VI input

 

 

 

15: RR input

 

 

 

16: RX input

12

Image 13
Contents E6580772③ Optional add-on cassette„ Transportation and Installation Safety Precautions„ Handling in general „ About operation „ Wiring„ About disposal of Inverter Introduction < Confirmation on accessories >< Type of F10M option unit > Contents Appearance Name and function of each sectionTLF001Z E6580772③ Name of each section terminal<When the unit is installed with another option> <When the unit is installed alone>Connection to the inverter Connection to the inverter„ Connection with options „ PG interface TB2 terminal E6580772③ WiringF10M communication function Functional descriptionConnection of transmission cable Setting of communication parameters „ F10M communication parameters Communication parametersE6580772 ③ „ Other parameters E6580772③ Vector control with sensor PG input setting↑V a Connection of PGInverter 100m Selection of encoder typeBasic parameters Vector control setting parameterExtended Parameter Speed loop integration gain Speed loop ratio gainSetting method for analog monitoring Setting method for status monitoringMonitoring method for feedback amount Accuracy of speed controlExternal diagram Environment Specification SpecificationPG feedback specification Specifications of transmission Warranty