Toshiba E6580772 instruction manual „ Connection with options

Page 9

E6580772

„Connection with options

When two or more optional add-on cassettes are used, connect them with reference to the following diagram.

Mounting of relay board for connecting options

Following the diagram below mount the board which is attached to the F10M option unit onto the unit for connecting options.

Insert a flat head screwdriver into the triangular section at the right side of the option unit and remove the small window cover.

Relay board mounting guide

Triangular mark on the side face

Slide the relay board into the place according to the insertion guide.

(Note) Engage the patterned section of the board with the metal pad section of the connector and insert the board in parallel. When the insertion angle inclines, remove the board once and try again.

Engage the patterned section of the board with the metal pad section of the connector and insert the board in parallel.

Connecting two options

Connect options with reference to the diagram below.

When the metallic parts of the relay board is touched with bear fingers, they oxidizes and the contacting failure occurs. Put on gloves for the work.

Triangular mark on the side face

Fit two option’s positioning guides on both units and connect two units not to shift the connecting position of the relay board. Hold a triangular section on the side of the unit and engage the relay boards securely.

(Connection is satisfactory when the click sound can be heard.)

If there is a gap between the units, two boards are misaligned. Carry out the work again from the beginning.

Option’s positioning guide (two guides on top and bottom)

8

Image 9
Contents E6580772③ Optional add-on cassetteSafety Precautions „ Transportation and Installation„ Handling in general „ Wiring „ About operation„ About disposal of Inverter < Confirmation on accessories > Introduction< Type of F10M option unit > Contents Appearance Name and function of each sectionTLF001Z E6580772③ Name of each section terminal<When the unit is installed with another option> <When the unit is installed alone>Connection to the inverter Connection to the inverter„ Connection with options „ PG interface TB2 terminal E6580772③ WiringFunctional description F10M communication functionConnection of transmission cable Setting of communication parameters „ F10M communication parameters Communication parametersE6580772 ③ „ Other parameters E6580772③ Vector control with sensor PG input setting↑V a Connection of PGInverter 100m Selection of encoder typeVector control setting parameter Basic parametersExtended Parameter Speed loop integration gain Speed loop ratio gainSetting method for analog monitoring Setting method for status monitoringMonitoring method for feedback amount Accuracy of speed controlExternal diagram Specification Environment SpecificationPG feedback specification Specifications of transmission Warranty