E6580772

Warning

Prohibited

Do not install the inverter in any place subject to vibrations or it could fall. Otherwise it can cause injury to people.

„Wiring

Danger

Mandatory

Be sure to perform the following preparatory work before proceeding to wiring.

Turn the power off.

Wait 10 minutes or more after turning the power off and confirm that the charge lamp (on the inverter) is extinct.

Using a circuit tester that has a D.C. voltage measuring capacity of more than 800V, check to see that the voltage remaining in the D.C. main circuit (between PC and PA) is below 45V.

Failure to do this preparation could lead to electric shocks.

Tighten the terminal board fixing screws at the specified torque. Failure to do this could lead to fire.

„About operation

Danger

Prohibited

Do not touch inverter terminals when they are energized even if the motor is halted. Touching terminals while the power is energized could lead to electric shocks.

Do not wipe the body with a wet cloth.

It could lead to electric shocks.

Do not pull on the cable

It could cause damage or error.

„About disposal of Inverter

Warning

Mandatory

Dispose of the inverter as an industrial waste.

Unless it is disposed of as an industrial waste, it will become risks for human injury.

2

Image 3
Contents E6580772③ Optional add-on cassetteSafety Precautions „ Transportation and Installation„ Handling in general „ Wiring „ About operation„ About disposal of Inverter < Confirmation on accessories > Introduction< Type of F10M option unit > Contents Appearance Name and function of each sectionTLF001Z E6580772③ Name of each section terminalConnection to the inverter <When the unit is installed alone><When the unit is installed with another option> Connection to the inverter„ Connection with options „ PG interface TB2 terminal E6580772③ WiringFunctional description F10M communication functionConnection of transmission cable Setting of communication parameters „ F10M communication parameters Communication parametersE6580772 ③ „ Other parameters E6580772③ Vector control with sensor PG input setting↑V a Connection of PGInverter 100m Selection of encoder typeVector control setting parameter Basic parametersExtended Parameter Speed loop integration gain Speed loop ratio gainAccuracy of speed control Setting method for status monitoringSetting method for analog monitoring Monitoring method for feedback amountExternal diagram Specification Environment SpecificationPG feedback specification Specifications of transmission Warranty