Sony Ericsson LBI-38965 CAL Operational Specifications, System Manager Interface

Page 16

LBI-38965

3.3. CAL OPERATIONAL SPECIFICATIONS

This section outlines the specifications that are unique to the CAL personality. Refer to Figure 4 for the CAL architecture.

3.3.1. System Manager Interface

The CAL interfaces to the System Manager's DECServer(s) via one or two terminal servers capable of supporting up to 32 independent asynchronous RS-232 serial connections. The ports on the CAL's terminal servers are connected to the ports on the System Manager's DECServers via RS-232 cables.

3.3.2. Protocol Supported

The CAL is capable of communicating with the System Manager using the System Manager-to-Site Controller (SM-SC) and Site Controller-to-System Manager (SC-SM) protocol defined in EDACS Protocol Specification, System Manager/Site Controller Version 1.1.

R FR F

S yste mS ystem

M IM

M IM

A re a

IM C

CAM

High-Speed H DLC

Link (R S-422)

TCP/IP

L AN

Centralized A ctivity Logger (C A L)

RS -232

CA L Console T erm inal

Em ulex Term inal Serv ers

Em ulex Term inal Serv ers

16RS -232

16R S-232

DEC

Term inal Serv ers

DEC

T erm inal Serv ers

System

M anager

D ECN et

LAN

Figure 4 - CAL Architecture

16

Image 16
Contents System and Installation Manual Table of Contents LBI-38965Table of Contents Introduction BCU/CAL ArchitectureCAL Functional Description BCU Functional DescriptionCall Types Supported Physical Specifications Physical Description and CompatibilityBCU/CAL Architecture TVME147 CPUCPU Compatibility Backwards CompatibilityCommon BCU and CAL Operational Specifications SpecificationsBCU Operational Specifications Billing Architecture Billing Architecture BCU Operation OverviewGroup Billing Mode RF Channel Usage Air TimeConversations Grouping CallsFile Name Contents Default Data Operator FunctionsDatabase Elements Unit DataCDR Processing Errors Call ProcessingCDR Processing Call Processing CDR OutputSystem Manager Interface CAL Operational SpecificationsProtocol Supported Additional Product Features Network File System CAL Operation OverviewInstallation Hardware InstallationSoftware Installation Installation Contents DisketteFile Name Usage Parameter MeaningEXPORTS.DAT Configuration File ParameterCAL.DAT Configuration File Directory Clientip EXPORTS.DAT File ParametersCAL.DAT File Parameters SITE01Initial Installation PrerequisitesInstallation Return Default System Accounts First-Time ConfigurationLogin Password Access Level Prerequisite User Information Entering bcs invokes the BCS programSystem Disk Booting Proper System Shutdown User Information Invoke the BCS programCAL Terminal Server Configuration Software UpgradesExample Configuration Tips Page Appendix a Edacs Billing CDR Format Overview Billing by ConversationBilling for Multiple Sites Record EncodingRecord Layout SINGLE-SITE CallsMULTIPLE-SITE Calls MOBILE-TO-LAND Telephone Interconnect CallsTable A.1 Call Detail Record Field Descriptions Name Size Format Range/Values DescriptionTable A.2 Call Types Call Type DefinitionsCall Type Description Valid with Hex Decimal Rec. Type A0-FF Call Type Bit Fields Table A.3 Call Type Bit Field DefinitionsCDR File Topics Appendix B Physical Configuration Details Jumper Settings Figure B.1 Tvme 147SA1 Single-Board Computer Figure B.2 Tvme 712/M Transition Module Figure B.4 fv5310 Main Board Figure B.5 fv5310 Mezzanine Card Scsi Connector Pwr DB-25F Signal Name Function Connector Cable PinoutsTable B.1 WANServer Port Table B.2 WANServer PortTable B.3 WANServer Port Table B.4 WANServer PortTable B.5 BCU/CAL Hdlc Loopback Cable Specification DB-25M Connector Signal Name Function BCU/CAL PortFigure B.9 CAL Terminal Server to Distribution Panel Cable A14 INM AC H106 Computer Terminal Appendix C Fault Tolerance Figure C.1 Edacs Billing Fault Tolerant Architecture Redundant Operation