5. RECORD LAYOUT

5.1. SINGLE-SITE CALLS

The following diagram shows the layout of the fields in a basic CDR for a single-site call. The top row shows the field name and number, the middle row shows the subfield name and letter, if applicable, and the bottom row shows the byte offset within the record.

1. Record

2. Node ID No.

 

3. Record ID No.

 

4. Start Date

 

 

 

 

 

 

 

5. Start Time

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a. System

b. Node

 

 

 

 

a. Year

 

 

 

b. Month

c. Day

 

a. Hour

b. Minute

c. Second

0

 

1

2

3

4

5

6

7

8

9

10

11

12

13

 

14

15

16

 

17

18

19

20

21

22

23

6.Call Type

7. Caller ID No.

8. Callee ID No.

24

25

26

27

28

29

30

31

32

33

34

35

36

37

 

38

 

39

40

 

41

42

43

44

45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9. Elapsed Time

 

10. Accumulated Air Time

11. No. of Channel

 

 

12. No. of

13. Site of Origin

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Assignments

 

 

 

Sites

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a. No.

 

b. Channel Map

 

 

 

46

47

48

49

50

51

52

53

54

55

56

57

58

59

 

60

 

61

62

 

63

64

65

66

67

68

69

Figure A.1 - Call Detail Record, Single-Site Call

5.2. MULTIPLE-SITE CALLS

A CDR may have 0 to n additional fields added beginning at byte offset 70, where n = No. of Sites - 1. The format of the additional fields is identical to the Site of Origin field (field 13) and is shown in the diagram below. The offset, x, of the first byte in each additional field is calculated as x = 62 + (8n).

13 +n. Additional Site n

a. No.

 

b. Channel Map

 

 

 

x

 

x+1

x+2

x+3

x+4

x+5

x+6

x+7

Figure A.2 - Call Detail Record, Additional Site Field

5.3. MOBILE-TO-LAND TELEPHONE INTERCONNECT CALLS

A CDR for a mobile-to-land telephone interconnect call will have an additional field beginning at byte offset 70. This field contains the digits dialed by the caller. A mobile-to-land call never involves multiple sites, so the PSTN Telephone Number field is never combined with the Additional Site fields described in the preceding section.

14. PSTN Telephone No.

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

101

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

..

Figure A.3 - Call Detail Record, PSTN Telephone Number Field

A-3

Image 37
Contents System and Installation Manual LBI-38965 Table of ContentsTable of Contents BCU/CAL Architecture IntroductionCAL Functional Description BCU Functional DescriptionCall Types Supported Physical Description and Compatibility Physical SpecificationsTVME147 CPU BCU/CAL ArchitectureCPU Backwards Compatibility CompatibilityCommon BCU and CAL Operational Specifications SpecificationsBCU Operational Specifications Billing Architecture BCU Operation Overview Billing ArchitectureRF Channel Usage Air Time Group Billing ModeConversations Grouping CallsFile Name Contents Operator Functions Default DataDatabase Elements Unit DataCall Processing CDR Processing ErrorsCDR Processing Call Processing CDR OutputSystem Manager Interface CAL Operational SpecificationsProtocol Supported CAL Operation Overview Additional Product Features Network File SystemHardware Installation InstallationInstallation Contents Diskette Software InstallationParameter Meaning File Name UsageParameter EXPORTS.DAT Configuration FileDirectory Clientip EXPORTS.DAT File Parameters CAL.DAT Configuration FileSITE01 CAL.DAT File ParametersPrerequisites Initial InstallationInstallation Return Default System Accounts First-Time ConfigurationLogin Password Access Level User Information Entering bcs invokes the BCS program PrerequisiteSystem Disk Booting User Information Invoke the BCS program Proper System ShutdownSoftware Upgrades CAL Terminal Server ConfigurationExample Configuration Tips Page Appendix a Edacs Billing CDR Format Billing by Conversation OverviewBilling for Multiple Sites Record EncodingSINGLE-SITE Calls Record LayoutMULTIPLE-SITE Calls MOBILE-TO-LAND Telephone Interconnect CallsName Size Format Range/Values Description Table A.1 Call Detail Record Field DescriptionsTable A.2 Call Types Call Type DefinitionsCall Type Description Valid with Hex Decimal Rec. Type A0-FF Table A.3 Call Type Bit Field Definitions Call Type Bit FieldsCDR File Topics Appendix B Physical Configuration Details Jumper Settings Figure B.1 Tvme 147SA1 Single-Board Computer Figure B.2 Tvme 712/M Transition Module Figure B.4 fv5310 Main Board Figure B.5 fv5310 Mezzanine Card Scsi Connector Pwr Cable Pinouts DB-25F Signal Name Function ConnectorTable B.1 WANServer Port Table B.2 WANServer PortTable B.4 WANServer Port Table B.3 WANServer PortDB-25M Connector Signal Name Function BCU/CAL Port Table B.5 BCU/CAL Hdlc Loopback Cable SpecificationFigure B.9 CAL Terminal Server to Distribution Panel Cable A14 INM AC H106 Computer Terminal Appendix C Fault Tolerance Redundant Operation Figure C.1 Edacs Billing Fault Tolerant Architecture