Sony Ericsson LBI-38965 Prerequisite, User Information Entering bcs invokes the BCS program

Page 28

LBI-38965

USER INFORMATION: Enter “ls” to observe the root level directory files and subdirectories which were created during the software installation process.

pSH+> ls

 

 

 

 

BITMAP.SYS

backup

etc

mnt

var

FLIST.SYS

bin

export

rar

 

LOADER.SX

cdr

loads

tmp

 

activity

cnfg

log

usr

 

USER INFORMATION: The following example shows the configuration files for the unit. The .BIN files were created during the software installation process.

pSH+> cd cnfg

 

 

 

 

 

 

pSH+> ls -als

 

 

 

 

 

 

total 41

 

 

 

 

 

 

2

-rwxrwxrwx

1

root

622

Feb 01 1994 10:45 CAL.DAT

2

-rwxrwxrwx

1

root

892

Feb 01

1994

10:45 IP.DAT

2

-rwxrwxrwx

1

root

568

Feb 01

1994

10:47 SYSTEM.BIN

1

-rwxrwxrwx

1

root

131072

Feb 01

1994

10:47 UNIT.BIN

33

-rwxrwxrwx

1

root

16384

Feb 01

1994

10:47 GROUP.BIN

USER ACTION: Two system parameters may need to be set. If the BCU/CAL is operating in a Multi- Node/StarGate configuration, the IMC NIM slot number needs to be defined. If the BCU/CAL service area (IMC) has a Jessica interconnect system installed, the IMC PIM slot number needs to be defined. These parameters must be set appropriately for the BCU to correctly provide billing for calls involving these “sites” (i.e., StarGate or Jessica). They are required by the CAL to simulate secondary drops from the site(s) it is providing service for. If the parameter (NIM or PIM slot) does not apply, it should be set to zero (default value).

These parameters are defined using the BCU/CAL Configuration Service (BCS) program. BCS is discussed in detail in LBI-38967. The following example is provided for reference to get the BCU set up and running as quickly as possible.

PREREQUISITE

1.Obtain the IMC slot number of the NIM and PIM modules, if any.

2.If not already logged into the BCU/CAL, log in under the "root" account as previously discussed. Enter the following commands at the indicated prompts.

USER INFORMATION: Entering "bcs" invokes the BCS program.

pSH+> bcs

Welcome to the BCU-CAL Configuration Service (BCS)

System Administrator privilege acknowledged.

USER INFORMATION: Entering "show system" displays the default system parameters that were initialized during the initial software installation.

BCS> show system

Default unit pseudo hangtime = 10

Default group pseudo hangtime = 10

Default group billing mode = Bill callee

Data call pseudo hangtime = 10

Data call billing = On

Phone digits mandatory = Off

CDR maximum file records = 1024

CDR sequence wrapping = On

28

Image 28
Contents System and Installation Manual Table of Contents LBI-38965Table of Contents Introduction BCU/CAL ArchitectureCAL Functional Description BCU Functional DescriptionCall Types Supported Physical Specifications Physical Description and CompatibilityBCU/CAL Architecture TVME147 CPUCPU Compatibility Backwards CompatibilityCommon BCU and CAL Operational Specifications SpecificationsBCU Operational Specifications Billing Architecture Billing Architecture BCU Operation OverviewGroup Billing Mode RF Channel Usage Air TimeConversations Grouping CallsFile Name Contents Default Data Operator FunctionsDatabase Elements Unit DataCDR Processing Errors Call ProcessingCDR Processing Call Processing CDR OutputSystem Manager Interface CAL Operational SpecificationsProtocol Supported Additional Product Features Network File System CAL Operation OverviewInstallation Hardware InstallationSoftware Installation Installation Contents DisketteFile Name Usage Parameter MeaningEXPORTS.DAT Configuration File ParameterCAL.DAT Configuration File Directory Clientip EXPORTS.DAT File ParametersCAL.DAT File Parameters SITE01Initial Installation PrerequisitesInstallation Return Default System Accounts First-Time ConfigurationLogin Password Access Level Prerequisite User Information Entering bcs invokes the BCS programSystem Disk Booting Proper System Shutdown User Information Invoke the BCS programCAL Terminal Server Configuration Software UpgradesExample Configuration Tips Page Appendix a Edacs Billing CDR Format Overview Billing by ConversationBilling for Multiple Sites Record EncodingRecord Layout SINGLE-SITE CallsMULTIPLE-SITE Calls MOBILE-TO-LAND Telephone Interconnect CallsTable A.1 Call Detail Record Field Descriptions Name Size Format Range/Values DescriptionTable A.2 Call Types Call Type DefinitionsCall Type Description Valid with Hex Decimal Rec. Type A0-FF Call Type Bit Fields Table A.3 Call Type Bit Field DefinitionsCDR File Topics Appendix B Physical Configuration Details Jumper Settings Figure B.1 Tvme 147SA1 Single-Board Computer Figure B.2 Tvme 712/M Transition Module Figure B.4 fv5310 Main Board Figure B.5 fv5310 Mezzanine Card Scsi Connector Pwr DB-25F Signal Name Function Connector Cable PinoutsTable B.1 WANServer Port Table B.2 WANServer PortTable B.3 WANServer Port Table B.4 WANServer PortTable B.5 BCU/CAL Hdlc Loopback Cable Specification DB-25M Connector Signal Name Function BCU/CAL PortFigure B.9 CAL Terminal Server to Distribution Panel Cable A14 INM AC H106 Computer Terminal Appendix C Fault Tolerance Figure C.1 Edacs Billing Fault Tolerant Architecture Redundant Operation