Sony Ericsson LBI-38965 installation manual Initial Installation, Prerequisites

Page 24

LBI-38965

4.2.2. Initial Installation

The following section discusses software installation on a new BCU/CAL. An example of the expected terminal display during this sequence is also provided. This example is annotated with comments indicating user activity/procedures during the installation, as well as general information regarding the process.

PREREQUISITES

1.Verify that the BCU/CAL unit does not have power currently applied.

2.Verify that the BCU/CAL is correctly connected to a VT100-compatible terminal (user console), the IMC CAM, and the local area network (LAN) (if applicable).

3.Verify that the user console is configured as follows:

a.9600 baud, 1 start bit, 1 stop bit, no parity.

b.VT100 personality. Terminal is DTE.

c.No translation of CR to CR/LF.

d.Local echo off. Tab stop at 8 characters.

e.DCE/DTE handshaking off.

f.XON/XOFF flow control is optional. The BCU/CAL does support flow control.

4.Edit the user configuration files contained on Installation Diskette 4.

a.Edit the text file, IP.DAT, to define the unit’s Internet parameters on the local network. If the unit will not have a network connection, the file IP.DAT may be left unmodified from that supplied with the release distribution.

b.If initial routing entries are desired, edit the file ROUTES.DAT.

c.If the NFS feature is purchased, edit EXPORTS.DAT. It is a template file for configuring NFS clients of the BCU/CAL. Client entries are specified as a BCU/CAL system disk directory, followed by the IP address of the client permitted to mount it. A log file (1.2/log/nfs.log) is generated on each system boot. The log summarizes processing of this file, indicating what has been exported, who received the export, and any errors encountered in this file. This file is processed during the application loading (boot) phase only. Modifications made after the unit is up and running will take effect during the next system boot.

d.If the BCU/CAL has been purchased with the CAL software feature, the file CAL.DAT on Installation Diskette 4 must be modified. This modification should define each site interface to the System Manager for which the CAL feature is to provide service. If the unit is only licensed for the BCU feature, the file CAL.DAT may be left unmodified from that supplied with the release distribution.

e.Reboot the BCU/CAL.

24

Image 24
Contents System and Installation Manual Table of Contents LBI-38965Table of Contents Introduction BCU/CAL ArchitectureBCU Functional Description CAL Functional DescriptionCall Types Supported Physical Specifications Physical Description and CompatibilityBCU/CAL Architecture TVME147 CPUCPU Compatibility Backwards CompatibilitySpecifications Common BCU and CAL Operational SpecificationsBCU Operational Specifications Billing Architecture Billing Architecture BCU Operation OverviewGroup Billing Mode RF Channel Usage Air TimeConversations Grouping CallsFile Name Contents Default Data Operator FunctionsDatabase Elements Unit DataCDR Processing Errors Call ProcessingCDR Processing Call Processing CDR OutputCAL Operational Specifications System Manager InterfaceProtocol Supported Additional Product Features Network File System CAL Operation OverviewInstallation Hardware InstallationSoftware Installation Installation Contents DisketteFile Name Usage Parameter MeaningEXPORTS.DAT Configuration File ParameterCAL.DAT Configuration File Directory Clientip EXPORTS.DAT File ParametersCAL.DAT File Parameters SITE01Initial Installation PrerequisitesInstallation Return First-Time Configuration Default System AccountsLogin Password Access Level Prerequisite User Information Entering bcs invokes the BCS programSystem Disk Booting Proper System Shutdown User Information Invoke the BCS programCAL Terminal Server Configuration Software UpgradesExample Configuration Tips Page Appendix a Edacs Billing CDR Format Overview Billing by ConversationBilling for Multiple Sites Record EncodingRecord Layout SINGLE-SITE CallsMULTIPLE-SITE Calls MOBILE-TO-LAND Telephone Interconnect CallsTable A.1 Call Detail Record Field Descriptions Name Size Format Range/Values DescriptionCall Type Definitions Table A.2 Call TypesCall Type Description Valid with Hex Decimal Rec. Type A0-FF Call Type Bit Fields Table A.3 Call Type Bit Field DefinitionsCDR File Topics Appendix B Physical Configuration Details Jumper Settings Figure B.1 Tvme 147SA1 Single-Board Computer Figure B.2 Tvme 712/M Transition Module Figure B.4 fv5310 Main Board Figure B.5 fv5310 Mezzanine Card Scsi Connector Pwr DB-25F Signal Name Function Connector Cable PinoutsTable B.1 WANServer Port Table B.2 WANServer PortTable B.3 WANServer Port Table B.4 WANServer PortTable B.5 BCU/CAL Hdlc Loopback Cable Specification DB-25M Connector Signal Name Function BCU/CAL PortFigure B.9 CAL Terminal Server to Distribution Panel Cable A14 INM AC H106 Computer Terminal Appendix C Fault Tolerance Figure C.1 Edacs Billing Fault Tolerant Architecture Redundant Operation