Sony Ericsson LBI-38965 installation manual Appendix C Fault Tolerance

Page 57

LBI-38965

APPENDIX C

FAULT TOLERANCE

C-1

Image 57
Contents System and Installation Manual LBI-38965 Table of ContentsTable of Contents BCU/CAL Architecture IntroductionBCU Functional Description CAL Functional DescriptionCall Types Supported Physical Description and Compatibility Physical SpecificationsTVME147 CPU BCU/CAL ArchitectureCPU Backwards Compatibility CompatibilitySpecifications Common BCU and CAL Operational SpecificationsBCU Operational Specifications Billing Architecture BCU Operation Overview Billing ArchitectureRF Channel Usage Air Time Group Billing ModeConversations Grouping CallsFile Name Contents Operator Functions Default DataDatabase Elements Unit DataCall Processing CDR Processing ErrorsCDR Processing Call Processing CDR OutputCAL Operational Specifications System Manager InterfaceProtocol Supported CAL Operation Overview Additional Product Features Network File SystemHardware Installation InstallationInstallation Contents Diskette Software InstallationParameter Meaning File Name UsageParameter EXPORTS.DAT Configuration FileDirectory Clientip EXPORTS.DAT File Parameters CAL.DAT Configuration FileSITE01 CAL.DAT File ParametersPrerequisites Initial InstallationInstallation Return First-Time Configuration Default System AccountsLogin Password Access Level User Information Entering bcs invokes the BCS program PrerequisiteSystem Disk Booting User Information Invoke the BCS program Proper System ShutdownSoftware Upgrades CAL Terminal Server ConfigurationExample Configuration Tips Page Appendix a Edacs Billing CDR Format Billing by Conversation OverviewBilling for Multiple Sites Record EncodingSINGLE-SITE Calls Record LayoutMULTIPLE-SITE Calls MOBILE-TO-LAND Telephone Interconnect CallsName Size Format Range/Values Description Table A.1 Call Detail Record Field DescriptionsCall Type Definitions Table A.2 Call TypesCall Type Description Valid with Hex Decimal Rec. Type A0-FF Table A.3 Call Type Bit Field Definitions Call Type Bit FieldsCDR File Topics Appendix B Physical Configuration Details Jumper Settings Figure B.1 Tvme 147SA1 Single-Board Computer Figure B.2 Tvme 712/M Transition Module Figure B.4 fv5310 Main Board Figure B.5 fv5310 Mezzanine Card Scsi Connector Pwr Cable Pinouts DB-25F Signal Name Function ConnectorTable B.1 WANServer Port Table B.2 WANServer PortTable B.4 WANServer Port Table B.3 WANServer PortDB-25M Connector Signal Name Function BCU/CAL Port Table B.5 BCU/CAL Hdlc Loopback Cable SpecificationFigure B.9 CAL Terminal Server to Distribution Panel Cable A14 INM AC H106 Computer Terminal Appendix C Fault Tolerance Redundant Operation Figure C.1 Edacs Billing Fault Tolerant Architecture