ACR-MOTIONMAX Installation Guide
28
Velocity=150 Sets Fast Jog Speeds 150
Stp=1 Set the Same as Acceleration 1
Step 19) Configure the Overrides

Note: These Parameters are set from Parameters Section [SoftwareOptions]

____________________________________________________________________
To Configure for Type 0 Override (Using Analog 10k Pot’s on Control Panel)
1. Set UseADCChanelForOverrides = 1
2. Set all 3 Override Types to = 0
3. Set all 3Max Override Value Parameters
4. Set all 3 OverridePotMaxVoltage Parameters
____________________________________________________________________
To Configure for Type 1 Override (Using Digital 4 Bit Pots on Control Panel)
1. Set UseADCChanelForOverrides = 0
2. Set All 3 Override Types to = 1
3. Set Max Override Value Parameters
4. Write code in AcroBasic that Sets the Digital_OVR bits of the Control Signals when digital pots
are rotated.
_____________________________________________________________________

(Default Mode)

To Configure for Type 98 Override (Using VB Screen sliders Exclusively for Overrides)
1. Set UseADCChanelForOverrides = 0
2. Set All 3 Override Types to = 98
3. Set Max Override Value Parameters
_____________________________________________________________________
To Configure for Type 99 Override (Hardcode Overrides to Max Values)
1. Set UseADCChanelForOverrides = 0
2. Set All 3 Override Types to = 99
3. Set Max Override Value Parameters (These Values will Be Constant for the Overrides)