Sony Ericsson LBI-38965 installation manual First-Time Configuration, Default System Accounts

Page 27

LBI-38965

**************************************************************

*

Welcome to the EDACS BCU/CAL.

*

*

 

*

* Copyright (C) Ericsson GE Mobile Communications

*

*

Mountain View Road

*

*

Lynchburg, Virginia 24502

*

*

1993,1994

*

**************************************************************

System boot complete: Wed May 4 13:55:09 1994

Login:

USER INFORMATION

The Welcome banner and Login prompt indicate a successful software installation and system boot. At this point, the operator should log into the unit under the "root" account to perform some first-time configuration operations.

4.2.2.1. First-Time Configuration

The following section describes the minimal set of system initializations that a user must perform to set up a BCU/CAL.

When the BCU/CAL software is first installed, three user accounts are initialized. Each account has a varying level of system access security. The following table defines the initial accounts and their passwords, arranged in decreasing levels of access. The login name and password are case-sensitive. These passwords can be changed from their default values, and new accounts installed, using the passwd command. Any new accounts added will have the same level of access as the "user" account.

 

 

Table 7 - Default System Accounts

 

 

 

Login

Password

Access Level

root

root

Anything. This account is the “super-user.”

admin

admin

Can access any BCS commands for system configuration.

user

user

Most restricted, particularly for the BCS commands.

 

 

 

Log onto the BCU/CAL under the "root" account. The console display will be similar to the following:

Login: root

Password:

Copyright (c) Integrated Systems, Inc., 1992. Welcome to pSOSystem...

pSH+>

27

Image 27
Contents System and Installation Manual LBI-38965 Table of ContentsTable of Contents BCU/CAL Architecture IntroductionBCU Functional Description CAL Functional DescriptionCall Types Supported Physical Description and Compatibility Physical SpecificationsTVME147 CPU BCU/CAL ArchitectureCPU Backwards Compatibility CompatibilitySpecifications Common BCU and CAL Operational SpecificationsBCU Operational Specifications Billing Architecture BCU Operation Overview Billing ArchitectureGrouping Calls Group Billing ModeRF Channel Usage Air Time ConversationsFile Name Contents Unit Data Default DataOperator Functions Database ElementsCall Processing CDR Output CDR Processing ErrorsCall Processing CDR ProcessingCAL Operational Specifications System Manager InterfaceProtocol Supported CAL Operation Overview Additional Product Features Network File SystemHardware Installation InstallationInstallation Contents Diskette Software InstallationParameter Meaning File Name UsageParameter EXPORTS.DAT Configuration FileDirectory Clientip EXPORTS.DAT File Parameters CAL.DAT Configuration FileSITE01 CAL.DAT File ParametersPrerequisites Initial InstallationInstallation Return First-Time Configuration Default System AccountsLogin Password Access Level User Information Entering bcs invokes the BCS program PrerequisiteSystem Disk Booting User Information Invoke the BCS program Proper System ShutdownSoftware Upgrades CAL Terminal Server ConfigurationExample Configuration Tips Page Appendix a Edacs Billing CDR Format Record Encoding OverviewBilling by Conversation Billing for Multiple SitesMOBILE-TO-LAND Telephone Interconnect Calls Record LayoutSINGLE-SITE Calls MULTIPLE-SITE CallsName Size Format Range/Values Description Table A.1 Call Detail Record Field DescriptionsCall Type Definitions Table A.2 Call TypesCall Type Description Valid with Hex Decimal Rec. Type A0-FF Table A.3 Call Type Bit Field Definitions Call Type Bit FieldsCDR File Topics Appendix B Physical Configuration Details Jumper Settings Figure B.1 Tvme 147SA1 Single-Board Computer Figure B.2 Tvme 712/M Transition Module Figure B.4 fv5310 Main Board Figure B.5 fv5310 Mezzanine Card Scsi Connector Pwr Table B.2 WANServer Port DB-25F Signal Name Function ConnectorCable Pinouts Table B.1 WANServer PortTable B.4 WANServer Port Table B.3 WANServer PortDB-25M Connector Signal Name Function BCU/CAL Port Table B.5 BCU/CAL Hdlc Loopback Cable SpecificationFigure B.9 CAL Terminal Server to Distribution Panel Cable A14 INM AC H106 Computer Terminal Appendix C Fault Tolerance Redundant Operation Figure C.1 Edacs Billing Fault Tolerant Architecture