Siemens M35 or S35, C35i manual Example, Initialization, Reset of GSM Remote Supervision

Page 11

Value of PIN of GSM gate set from production and after initialization is 0000. PIN 0000 shall not be set into cell phone from gate so that blockage of phone is not caused during first contacts with gate.

Example:

Original PIN of GSM gate is 0000. SIM card, which you use in cell phone in GSM gate has PIN 1234 and is blocked by PIN.

Insert the SIM card into the mobile phone, but do not connect the GB 051 connector yet. Insert the required PIN in the mobile phone (e.g. 1234). Go into the mobile phone menu and select Settings – Security – Codes – Change PIN then insert the old PIN and the new PIN according to the mobile phone instructions.

Send a command SMS message with text XX0000PINV1234 from cell phone or Internet on cell phone number in the unit.

As soon as a confirmation SMS message comes back to sender’s cell phone the new PIN is set to value “1234”

User can verify the PIN change by switching the phone off.

Initialization:

In case you forget current PIN of GSM Remote Supervision you have no choice than to carry out initialization of parameters to original set-up from production. It shall be carried out in following steps:

1.Disconnect external power supply. (throw up power adapter)

2.Disconnect the mobile phone connector.

3.Interconnect inputs GROUND and INIT (terminals No. 1 and 2, see Chapter 3.2.) on terminal board

4.Connect external power supply. (throw in power adapter)

5.Remove connection GROUND – INIT

6.Disconnect external power supply. (throw up power adapter)

7.Connect the mobile phone to the GB 051 unit – the PIN must be preset to value “0000”.

8.Connect external power supply.

9.PIN and other required parameters have to be set-up again

4.2.RESET of GSM Remote Supervision

If you want to carry out remote reset of counters of days and months in operation then send SMS message with Command RESET. Command is rejected if GB 051 runs from backup battery.

Command

XXppppRESET

Pppp

Four digits of current PIN

Function is equivalent to disconnection of gate from power supply (also backup one) and its re-connection.

11

Image 11
Contents Level Dear Customers Table of Contents GSM Remote Supervision GB Product Description Description of Function Contents of Delivery Wiring and connecting the GSM Remote Supervision unit Recommended linkage of outputs Recommended linkage of inputs Inserting the SIM Card and Connecting to the Cell PhonePIN Is the key word of the commandXX0000PINVpppp 0000Quick flashes Indication by LEDSlow regular flashing Occasional short flashPIN in GSM Remote Supervision Change of PIN CommandSpace follows Parameter Initialization Reset of GSM Remote SupervisionCommand XXppppRESET Pppp Four digits of current PIN ExampleIcall Regular Calling Free of Charge Command XXppppINIT Pppp Four digits of current PINCommand Pppp Init Re-initialization of Values Set from ProductionInfosms Sending of Information Messages about Operation Acall Automatic Alarm CallingText Alarmsms Alarm SMS MessagesCommand *1 Initial set-up Input Order on Terminal Board Change of numbers for sending Alarm SMS messagesIO4 IO1IO2 IO3Callback Monitoring of Protected Area List Detection of Set-upProgramming from PC Operation during Failure of External Power SupplyCommand XXpppp Range Set List of Programming Commands Control SMS MessagesGSM network Basic Technical ParametersInputs of SMS messages No Outputs of SMS messages NoGuarantee Certificate Guarantee Conditions Statement of Consensus Page GB 051@1.02 Level