If you only want to change value of output regardless of previous state send command without parameter “y” – e.g. XXppppOUT5 changes value of output No. 5 to reverse.
Newly set actual values of all 8 inputs/outputs are sent back to sender and to INFOSMS number.
4.11. LIST – Detection of Set-up
If you want to find out which values of parameters are set in GB 051 it is possible to send control SMS message, which initiates sending messages with detailed description of
| XXppppLISTVi *1) |
Command |
ppppFour digits of current PIN
i | IO number: 1 to 8, with no parameter will return the |
| shared configuration |
*1) The space is between | key word of command “LIST” and “i” |
SMS command messages intended for getting parameter configuration of each input/output
The GB 051 unit will return sender a message with the required configuration information related to the particular IO:
∙Actual value of logical level of the particular input.
∙
∙
∙
∙
IO value, acall, aSMSnoA, aSMSnoB, SMStxt
In case the command SMS message is sent with no parameter, the GB 051 unit will respond to the sender with message containing five basic configuration data:
infoSMS number, infoSMS interval, icall number, icall interval, mcall number
4.12. CALLBACK – Monitoring of Protected Area
If you want to find out by listening – e.g. during alarm – what is happening in place of installation it is possible to require, by SMS message, to get further call from GB 051 with
Command *1) XXppppCALLBACKVnumber
ppppFour digits of current PIN
| Maximum 14 digits of any phone number *2) |
Number |
*1) The space is between key word of command „CALLBACK“ and number.
*2) If no number is specified GB 051 calls back the number of sender of SMS command. Number can be entered in national format – e.g. 606445566 but also in international format – e.g. +420606445566.