Siemens C35i, M35 or S35 manual List Detection of Set-up, Callback Monitoring of Protected Area

Page 16

If you only want to change value of output regardless of previous state send command without parameter “y” – e.g. XXppppOUT5 changes value of output No. 5 to reverse.

Newly set actual values of all 8 inputs/outputs are sent back to sender and to INFOSMS number.

4.11. LIST – Detection of Set-up

If you want to find out which values of parameters are set in GB 051 it is possible to send control SMS message, which initiates sending messages with detailed description of set-up back to sender.

 

XXppppLISTVi *1)

Command

ppppFour digits of current PIN

i

IO number: 1 to 8, with no parameter will return the

 

shared configuration

*1) The space is between

key word of command “LIST” and “i”

SMS command messages intended for getting parameter configuration of each input/output 1–8:

The GB 051 unit will return sender a message with the required configuration information related to the particular IO:

Actual value of logical level of the particular input.

Pre-set phone number for ALARM call.

Pre-set number A for ALARM SMS for the particular input.

Pre-set SMSNO B for the input.

Pre-set SMSTXT – text of the message of the input.

IO value, acall, aSMSnoA, aSMSnoB, SMStxt

In case the command SMS message is sent with no parameter, the GB 051 unit will respond to the sender with message containing five basic configuration data:

infoSMS number, infoSMS interval, icall number, icall interval, mcall number

4.12. CALLBACK – Monitoring of Protected Area

If you want to find out by listening – e.g. during alarm – what is happening in place of installation it is possible to require, by SMS message, to get further call from GB 051 with switched-on microphone for room monitoring.

Command *1) XXppppCALLBACKVnumber

ppppFour digits of current PIN

 

Maximum 14 digits of any phone number *2)

Number

*1) The space is between key word of command „CALLBACK“ and number.

*2) If no number is specified GB 051 calls back the number of sender of SMS command. Number can be entered in national format – e.g. 606445566 but also in international format – e.g. +420606445566.

16

Image 16
Contents Level Dear Customers Table of Contents GSM Remote Supervision GB Product Description Description of Function Contents of Delivery Wiring and connecting the GSM Remote Supervision unit Inserting the SIM Card and Connecting to the Cell Phone Recommended linkage of outputs Recommended linkage of inputsIs the key word of the command XX0000PINVpppp0000 PINIndication by LED Slow regular flashingOccasional short flash Quick flashesSpace follows Parameter Change of PIN CommandPIN in GSM Remote Supervision Reset of GSM Remote Supervision Command XXppppRESET Pppp Four digits of current PINExample InitializationCommand XXppppINIT Pppp Four digits of current PIN Command PpppInit Re-initialization of Values Set from Production Icall Regular Calling Free of ChargeAcall Automatic Alarm Calling Infosms Sending of Information Messages about OperationAlarmsms Alarm SMS Messages Command *1 Initial set-up Input Order on Terminal BoardChange of numbers for sending Alarm SMS messages TextIO1 IO2IO3 IO4List Detection of Set-up Callback Monitoring of Protected AreaOperation during Failure of External Power Supply Programming from PCList of Programming Commands Control SMS Messages Command XXpppp Range SetBasic Technical Parameters Inputs of SMS messages NoOutputs of SMS messages No GSM networkGuarantee Certificate Guarantee Conditions Statement of Consensus Page GB 051@1.02 Level