RESET By connection clips no. 2 and 3 (ground and reset) the unit reset will be run, while all the set configuration value will remain in place.
The value of days in service will be set to 0.
INIT Detailed description of how to carry on the initialization can be found in Chapter 4.1. The GSM Remote Control device will be set into default manufacturer’s settings by the initialization.
Recommended linkage of outputs:
Recommended linkage of inputs:
If GSM signal is insufficient external antenna can be connected to cell phone.
Professional solution of switching electrical devices on and off is provided by the 230 V/5 A double power switch ED 050 300 that can be purchased as optional accessory.
For connection with a PC use always the ED 051 011 converter with cable that connects into the connector at the bottom side of the unit and into the RS 232 interface in your PC. If you need to connect the PC using the older ED 050 001 converter, use the new optional accessory ED 051 050 (cable with reduction, Control Panel software included).
The GB 051 device is able to work fully without external power supply for approximately 12 hours being supplied from the mobile phone battery.
3.3. Inserting the SIM Card and Connecting to the Cell Phone
GSM Remote Supervision can be used only with cell phones Siemens C35, M35 and S35. Do not attempt to connect other phones, it may cause device or phone damage.
Always use only NiMH battery with the GB 051. Using a
7